A/C SYSTEM SPECIFICATIONS
SPECIFICATIONS
Application Specification
Compressor Type .................... Zexel DKS-15CH 6-cyl.
Compressor Belt Tension (1)
Compressor Oil Capacity ..................... ( 2) 6.8 ozs.
Refrigerant Capacity (R-134a) .................. 26.4 ozs.
System Operating Pressures (3)
High Side ............... 406-450 psi (28.5-31.6 kg/cm
)
Low Side .................... 25-33 psi (1.8-2.3 kg/cm
)
(1) - Belt tension is maintained by automatic belt tensioner.
(2) - Use PAG Oil (Part No. 11 61 407-0)
(3) - Pressure switch cut-out points.
DESCRIPTION
The Electronic Climate Control (ECC) module (A/C-heater
control panel) contains a function selector dial, driver’s and
passenger’s temperature dials, a REC (recirculated air) switch, A/C
OFF switch, and a fan speed (blower motor) control lever. See Fig. 1.
The heater (blower motor) fan is controlled by ECC output (power)
stage. Air conditioning system will only operate above 32
F (0
C).
Blower switch must not be in zero position to allow compressor to
engage.
Other system components include an A/C relay, A/C compressor,
low-pressure switch (pressostat), A/C safety and high-pressure switch,
engine coolant temperature sensor, outside temperature sensor,
interior temperature sensors, and duct temperature sensors.
In addition, driver’s and passenger’s temperature control
damper motors, recirculation damper motor, floor/defroster damper
motor, ventilation damper motor, and diagnostic connectors (units)
complete system.