Installation Instructions
IS6300-R05/10
Copyright © 2011 Ingersoll-Rand. All rights reserved.
6300 Surface Mounted Rim Strike
Important: The New 6300 Electric Strike is never to be used as a door stop. Please install stops on frame
in appropriate locations. Ensure the exit device functions as intended for life safety concerns by verifying
electric strike and exit device compatibility. Maximum latch projection is essential to obtain full holding force.
When installed in a fail secure manner, the local Authority Having Jurisdiction shall be consulted with regard
to the use of selected panic hardware to ensure emergency exit from the secured area.
Catalog Specifications
Model Mode Voltage Current Duty Amps Ohms
6300 Fail Secure 12V DC Continuous 0.50 22
6300 Fail Secure 24V DC Continuous 0.24 89
Fail Locked = Fail Secure = FSE DC = Direct Current
Continuous Duty = Energized 1 minute or more
Dimensional Details
3/4"
(19.0mm)
1-5/8"
(42.0mm)
9"
(228.6mm)
8-1/4"
(209.6mm)
1-3/4"
(44.5mm)
5-1/2"
(139.7mm)
HORIZONTAL
ADJUSTMENT
MOUNTING
HOLES
LOCK DOWN
HOLES