www.vtdrive.com
This code is used
to set the “soft
starting
time”
If the code is set as “0”,the
motor will “staring mode”
This code is used
to set the time of“
start-up time delay”
By the count-down way, If set as
“0”, the starter will start up the
motor Immediately without
time-delay.
This code is used
to
time of
“programming
output
time-delay”
Be used with” programming
relay output”
This code is used
to
set the “Interval
start
time-delay”
Be used when you need or have
to
Re-start the motor for several
times, or Re-start the motor after
removing the over-heat protection
for motor.
This code is used
to
set the “start-up
limit
current value”
It is used when the staring mode
is “Limit-current”, and the value
will be fixed as 400% when the
starting mode is” Ramp voltage to
start”