VENTILATOR MOUNTING
Operation Instruction for the user and the qualified installer
11
1. Prepare a round hole through in the
wall. The hole size is shown below.
3. Install a telescopic air duct inside
the wall. The telescopic air duct end
must protrude to the distance A
stated below:
4. Connect the mounting plate
following the wiring diagram, page
15. Pr
epar
e four fastening holes and
fix the mounting plate on the wall
with four 4x40 screws and 6x40
dowels (included in the delivery set).
Align the telescopic air duct to the
mounting plate and fill the gaps
between the wall and the telescopic
air duct with a mounting foam. The
telescopic air duct must not
protrude from the mounting plate
surface.
2. After preparing a through hole cut
out a 25 mm (r) deep recess for laying
of the cables and the contact sockets
connected to the mounting plate.
The recommended recess profile is
shown in the drawing below.
Ø180
A
A
SECTION A-A
max A
200
180
Ø6
Ø180
max200mm(max7
max90mm
(max7
R100
(R4”)
9
16“
7
8“
Inside
Outdoors