LAKEPRO-1 WI-FI TOUCHSCREEN
PROGRAMMABLE THERMOSTAT

Questions and Answers

  • L
    lidanielleAug 19, 2025
    What to do if heating or cooling does not come on with Vtronix Thermostat?
    • C
      Clinton DrakeAug 19, 2025
      If your heating or cooling system isn't starting, there are several potential causes: * The thermostat's minimum off-time may be active. If the screen displays 'Wait', allow up to five minutes for the system to respond. * The system selection may not be set to Heat or Cool. Ensure the system selection is set to the correct value. * The system type selection could be incorrect. Verify the correct system type is selected in Installer Setup submenu 0170.
  • E
    Eric CampbellAug 21, 2025
    What to do if temperature settings do not change on Vtronix LAKEPRO-1 Thermostat?
    • A
      Angela HicksAug 21, 2025
      If you're unable to adjust the temperature settings on your Vtronix Thermostat, it could be due to: * Reaching the upper or lower set temperature limits. Check the set temperature limits in Installer Setup submenu 0600 or 0610 and modify them as needed. * The touchpad being fully locked. Check Installer Setup submenu 0670 to change the touchpad lock options.
  • P
    Patricia GarciaAug 25, 2025
    What to do if Vtronix LAKEPRO-1 is calling for Heat or Cool but no heating or cooling?
    • J
      James PhelpsAug 25, 2025
      If your Vtronix Thermostat indicates it's calling for heat ('Heat on') or cool ('Cool on') but there's no actual heating or cooling, the cause may be that the heating or cooling equipment is not operating. In this case, check the wiring and verify the correct system type is selected in Installer Setup submenu 0170.
  • J
    James ReyesAug 26, 2025
    Why does my Vtronix LAKEPRO-1 Thermostat display 'Wait'?
    • J
      james76Aug 26, 2025
      The 'Wait' message on your Vtronix Thermostat indicates that the compressor minimum off timer is active. Allow up to five minutes for the cooling or heating (heat pump) equipment to turn on.
  • M
    Michelle RiosAug 28, 2025
    Why is my heat pump putting out cool air in heat mode with Vtronix Thermostat?
    • T
      Tracy SanchezAug 28, 2025
      If your heat pump is emitting cool air when in heat mode and warm air when in cool mode, the changeover valve may not be configured correctly for your installed heat pump. Set the Changeover Valve in Installer Setup submenu 0190 to match the changeover requirements of your heat pump.
  • K
    Kimberly CisnerosAug 30, 2025
    How to unlock the touchpad on a Vtronix LAKEPRO-1 Thermostat?
    • D
      Dr. Joseph RogersAug 30, 2025
      If the Touchpad Locked icon (padlock) is displayed on the screen and the keys of your Vtronix Thermostat are unresponsive, the touchpad is locked. Enter Installer Setup by pressing the System key for 5 seconds. Then, go to Installer Setup submenu 0670 to change the touchpad lock options.
  • M
    Megan DurhamSep 1, 2025
    What to do if heating equipment is running in cool mode with Vtronix Thermostat?
    • S
      scottlindsaySep 1, 2025
      If your heating equipment is running in cool mode, it's possible that the System Type in Installer Setup submenu 0170 is incorrectly set to Heat Pump, even though your heating equipment isn't a heat pump. Set the System Type in Installer Setup submenu 0170 to accurately reflect your installed heating and/or cooling equipment.
  • D
    Dr. Tommy Hunter Jr.Sep 3, 2025
    Why won't my Vtronix Thermostat display Heat On?
    • T
      Tanya BellSep 3, 2025
      Your Vtronix Thermostat may not display 'Heat On' if the system is not set to Heat, or if the set temperature is not above the current room temperature. Ensure the system setting is set to Heat and that the temperature setting is higher than the room temperature.
  • A
    Amy CooperSep 5, 2025
    Why won't my Vtronix LAKEPRO-1 Thermostat display Cool On?
    • E
      Edward RobersonSep 5, 2025
      Your Vtronix Thermostat may not display 'Cool On' if the system is not set to Cool, or if the set temperature is not below the current room temperature. Ensure the system setting is set to Cool and that the temperature setting is lower than the room temperature.
  • L
    Latoya AndersonSep 7, 2025
    What causes both heating and cooling to run at the same time on Vtronix Thermostat?
    • J
      jimenezcarolineSep 8, 2025
      If both your heating and cooling systems are running simultaneously, there are two potential causes: * If the heating equipment is not a heat pump but the System Type is set to Heat Pump, set the System Type in Installer Setup submenu 0170 to match the installed heating and/or cooling equipment. * Heating and cooling wires may be shorted together. Separate the shorted heating and cooling wires.

Summary

Specifications

Installation

Installing the Wall plate

Step-by-step guide for mounting the wall plate on drywall or electrical boxes.

Wiring

Powering Up the Thermostat

Programming the Thermostat

Installer Setup

Table 2. Installer Setup Menu

Lists installer setup options, their default values, and notes for configuration.

System Type Selection

Details on selecting the correct system type for proper thermostat operation.

Minimum Compressor Off Time

Sets the minimum off-time for the compressor to prevent damage.

Operation

User Setup

Date;Time Setting

Selecting the System Mode

Set Temperature Overrides

Permanent Hold

Connecting to your Wi-Fi Network

Programming a Schedule

Troubleshooting

No LCD Display

Troubleshooting steps for when the thermostat display is blank.

Temperature Settings Do Not Change

Possible causes and actions for temperature setting issues.

Heating or Cooling Does Not Come On

Troubleshooting steps for when the heating or cooling system is not activated.

System Signals Operation, No Response

Diagnosing issues when the thermostat signals operation but the system does not respond.

Vtronix LAKEPRO-1 Specifications

General IconGeneral
BrandVtronix
ModelLAKEPRO-1
CategoryThermostat
LanguageEnglish