Do you have a question about the WAC Lighting EN-1260-RB2 and is the answer not in the manual?
Always turn off power before installation and ensure installation by a qualified electrician, adhering to codes.
Features auto-reset for short circuit and overload protection, plus automatic thermal regulation.
Includes a soft start delay mechanism designed to preserve bulb life, specifically for tungsten filament lamps.
Use #18 AWG output wire, install away from heat, connect to like-colored wires, and ensure proper grounding.
Connect output wires to fixture wires using wire nuts, joining multiple fixture wires if needed.
Provides guidelines for maximum wire lengths based on wattage (20W, 40W, 60W) and wire gauge (18, 16, 14, 12 AWG).
| Input Voltage | 120V |
|---|---|
| Output Voltage | 12V |
| Wattage | 60W |
| Material | Metal |
| Finish | Black |
| Maximum Load | 60W |
| Frequency | 50/60 Hz |
| Operating Temperature | 0°C to 40°C |
| Protection | Short Circuit |
| Type | Electronic Low Voltage Transformer |