BA D24 en/us* 1.0 * D24_1_0_700.fm 7-25
Maintenance 7
Information
Check the coolant level once a day before starting the engine.
Observe the coolant compound table
Checking the coolant level
1. Stop and park the vehicle. Stop the engine see "Preparing
lubrication" on page 7-6.
2. Open the engine cover.
3. Check the coolant level on sight glass A.
4. If the coolant level is below the FULL mark:
Add coolant.
5. Close and lock the engine cover.
Adding coolant
1. Stop and park the vehicle. Stop the engine see "Preparing
lubrication" on page 7-6.
2. Open the engine cover.
3. Carefully unscrew filler cap B and release the pressure.
4. Open filler cap B.
5. Top off coolant up to the FULL mark.
6. Close filler cap B.
7. Start the engine and let it warm up for about 5 – 10 minutes.
8. Stop the engine.
9. Remove the starting key and carry it with you.
10.Let the engine cool down.
11.Check the coolant level again.
12.If necessary, add coolant and repeat the procedure until the coolant
level remains constant.
13.Close and lock the engine cover.
Fig. 167
A
FULL
Fig. 168
B
FULL