26
Labels GP
h WARNING
Hot surface
j Electrical ground
k Important Emissions Information
This equipment meets California EVP emission
regulations for small off-road engines.
m Emission Control Information
This equipment meets U.S. EPA EVAP
standards.
n NOTICE
Lifting point
o
GFCI TEST INSTRUCTIONSTEST—BEFORE EACH USE
Normal operating state - sensing device green LED is ON and circuit breaker is at ON position.
1: Press TEST button. Green LED should go OUT, red LED should come ON, and circuit breaker
should trigger to OFF position.
2: If sensing device LED or breaker does not trip or change state, DO NOT USE. Consult an
electrician for assistance.
3: Press RESET button. Red LED should turn OFF and green LED should turn ON.
4: Manually reset (switch) circuit breaker to ON position to restore circuit power.
This machine may be covered by one or more
patents.
GND
88897