EasyManuals Logo

Wacker Neuson PT2R User Manual

Wacker Neuson PT2R
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
PT2R OPERATION 1A
1A-15
1.28 Storage
If pump is being stored for more than 30 days:
1. Remove drain plug from pump cover and drain out any
water left in the housing.
2. Remove pump cover and clean inside of pump hous-
ing. Coat inside of pump with a light film of oil to reduce
corrosion. A spray can of oil works well for this.
3. Tape up suction and discharge ports to prevent
anything from falling into pump.
4. Change engine oil and follow procedures described in
engine manual for engine storage.
5. Cover pump and engine and store in a clean, dry area.
1006SD74
f
g
1.27 Throttle Adjustment
1. Start engine and allow it to warm up to operating
temperature.
2. Move throttle control to high speed position
(f).
3. Adjust throttle stop screw
(g) to set operating speed.