EN
12
SteamForce Pro
16. Correction of Malfunctions
Malfunction Cause Remedy
Unit fails to boil
•
The thermal cut-out has operated
•
Usage of an extension lead
Switch o, allow to
cool, rell with water
then switch on again
Check that the thermal
reset button has not
tripped out.
Check that the
extension lead is rated
at minimum of 15
Amps (EU)/ 13 Amps
(UK) - 230V unit only
and fully unwound.
Unit keeps cutting
out
•
Water is below MIN level
•
Usage of an extension lead
•
Additives have been used
Rell water
See above
Refresh water
Steam escaping
from pressure cap
•
Blockage in hose or steamplate
•
Build up around cap area
Remove blockage
Clean seating around
cap area
i
If the unit still will not operate return the unit to the dealer or authorised agent
for investigation.
17. Technical Data
Power source: 220-240 V ~ 50Hz Power consumption: 2750W
Steaming time:
80-100 Minutes Hose length: 5 m
Boiler capacity:
7.5L Unit weight: 9.4kg
Max persons: 1 Max standing weight: 127kg
18. Accessories
Further information about the WAGNER range of products for decorative preparation is
available on www.wagner-group.com.