WALDOOR AUTOMATIC DOORS
Accustraat 21, P.O. Box 94, 3900 AB, Veenendaal (NL), Tel.: +31 (0)318-532333, Fax: +31 (0)318-532339
Traderegister 30080679, E-mail: waldoor@waldoor.nl, Internet: www.waldoor.nl
User Instruction Waldoor
®
Sliding Door Operator UWS and WM1-A
1. Line cable (230V AC with earth)
2. Motion detector
3. Cover
4. Fixed side panel
5. Door leaf
6. Photocells (1 or 2 sets)
7. Programme switch (PGS)
8. 3-Position programme selector switch
9. Night switch (key or pushbutton)
10. Handle (optional) for hermetical doors
11. Manual unlocking (optional)
Display:
-8-
General fault. See the display in the PCB
-A
- Battery fault. (Press 1 x on “reset”. The battery
test is repeated after 1 hour, etc.).
-0-
Same as -A- on older versions type 2. (Visible
on the PGS after switching on the line power).
-E-
Pull open cord defect.
By pushing shortly the
RESET
button on the PGS,
the com
p
uter tries to re
p
air a
p
ossible fault
Programming
Wo = winter open width
So = open speed
Sc = close speed
To = open time
·
Push RESET ± 5 sec. until all led’s
are flashing.
·
Press repeatable on the desired
button (So, Sc of To) and select the
right value 0 (min.) until 9 (max.)
·
Close by pressing RESET.
WINTERSTAND
IN /UIT
Learning cycle:
During a delay time of 5 sec. the
PGS
shows a “
3
” (or a “
2
” on older versions) and
all led’s are on.
A
fter these 5 seconds all led’s are off except
A
UTOMATIC.
The door will close now maximum on the
lowest speed the computer has found.
A
fter that the door will fully open on the
lowest speed. During this opening cycle a
brake test is carried out.
A
fter the door has fully opened against the
end stop the door will close on normal speed
and is ready to use.
Use of the programme switch (PGS)
Automatic
Exit
Closed
(
optional locked)
open
Winter position
Sequence function
Display
Reset button
Hard Reset:
1- Switch off and on again the 230V or
2- (
³
1.90) Press reset 5 sec. until all led’s
are flashing and then 5 sec. on the
sequence button until all led’s are off.
Question and Answer IconNeed help?

Do you have a question about the Waldoor UWS and is the answer not in the manual?

Waldoor UWS Specifications

General IconGeneral
BrandWaldoor
ModelUWS
CategoryDoor Opening System
LanguageEnglish

Summary

Programme Switch (PGS) Operation and Settings

Programme Switch (PGS) Usage

Details the various positions and functions of the Programme Switch.

Programming Door Parameters

Explains how to set parameters like open width, speed, and open time.

Display Fault Codes and Reset

Lists error codes displayed on the PCB and describes fault repair.

Learning Cycle Procedure

Describes the door calibration process for optimal operation.

Additional Door Operator Functions

3-Position Selector Switch Functions

Outlines functions activated by the 3-position selector switch.

Nightswitch Functionality

Explains how the nightswitch affects motion detectors.

Power Failure Operation

Details how the doors can be operated during power outages.

Safety and Service Information

Important Safety Attention Points

Provides critical warnings regarding door operator safety and installation.

Service Troubleshooting Checklist

Offers a list of checks before contacting the service department.