Heating Return Temperature Sensor Error
The temperature sensor is faulty or
disconnected.
Test the operation of the heating
return temperature sensor and
re-connect/replace if necessary.
Heating Flow Temperature Sensor Error
The temperature sensor is faulty or
disconnected.
Test the operation of the heating
flow temperature sensor and re-
connect/replace if necessary.
DHW Cylinder Temperature Sensor Error
The temperature sensor is faulty or
disconnected.
Test the operation of the DHW
cylinder temperature sensor and
re-connect/replace if necessary.
Ambient Temperature Sensor Error
The temperature sensor is faulty or
disconnected.
Test the operation of the ambient
temperature sensor and re-
connect/replace if necessary.
Suction Temperature Sensor Error
The temperature sensor is faulty or
disconnected.
Test the operation of the
refrigerant suction line
temperature sensor and re-
connect/replace if necessary.
Evaporator Temperature Sensor Error
The temperature sensor is faulty or
disconnected.
Test the operation of the
evaporator temperature sensor
and re-connect/replace if
necessary.
Discharge Temperature Sensor Error
The temperature sensor is faulty or
disconnected.
Test the operation of the
refrigerant discharge line
temperature sensor and re-
connect/replace if necessary.
Discharge Overheat Temperature Sensor
Error
The temperature sensor is faulty or
disconnected.
Test the operation of the
discharge line overheat
temperature sensor and re-
connect/replace if necessary.
Discharge Pressure Sensor Error
The pressure sensor is faulty or disconnected.
Test the operation of the
refrigerant discharge line
pressure sensor and re-
connect/replace if necessary.
Suction Pressure Sensor Error
The pressure sensor is faulty or disconnected.
Test the operation of the
refrigerant suction line pressure
sensor and re-connect/replace if
necessary.