EasyManua.ls Logo

WarmlyYours TempZone User Manual

Default Icon
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
11
Free Design Service • 24/7 Installation Support • No Nonsense™ Warranty • (800) 875-5285 • www.WarmlyYours.com
Installation Manual for your
TempZone™ Electric Radiant
Floor Heating System (Twin Conductor)
Question and Answer IconNeed help?

Do you have a question about the WarmlyYours TempZone and is the answer not in the manual?

WarmlyYours TempZone Specifications

General IconGeneral
BrandWarmlyYours
ModelTempZone
CategoryFloor Heating Systems
LanguageEnglish

Summary

Understanding The System

How The System Works

Explains the principle of radiant energy transfer and how the system warms a room.

Protecting The Heating Element

Emphasizes careful handling to avoid damaging the heating element during installation.

Never Cut The Heating Element

States that the heating element's integrity is key and it should never be cut.

Control Device Options

Presents different thermostat options available for the system.

Items Needed For The System Installation

Ground Fault Circuit Interrupter

Explains the function of GFCI protection for safety.

Digital Ohm Meter (multi-meter)

Stresses the importance of using a digital ohm meter for testing the heating rolls.

Understanding The Customized Installation Plan

Navigating Turns and Free Form Spaces

Cut & Turn Techniques

Explains how to cut mesh to create panels and make turns.

Advanced Installation Techniques

Step Turn Methods

Illustrates how to make U-turns and 180° flip turns using mesh cuts.

System Testing and Ohm Readings

Critical Safety: No Power During Testing

A critical warning about not energizing the system before installation is complete.

When to Take Ohm Readings

Advises on when to perform Ohm readings: before, during, and after installation.

Recording and Verifying Ohm Readings

Explains how to record and compare Ohm readings against the UL label and warranty card.

Measuring Ohm Resistance Accurately

Details how to measure Ohm resistance between conductors and sheath, and required meter settings.

Wiring a Control to Twin Conductor

Step-by-Step Wiring Procedure

Lists sequential steps for safely wiring the system components, including breaker status.

Installer's Guide: Planning and Preparation

STEP 5 Installation Precautions

Emphasizes careful handling to prevent damage to the heating element during installation.

Electrician's Guide: Troubleshooting

Continuity Checker Warning

Warns against using continuity checkers and recommends a digital Ohm meter.

Electrical Fault-Finding Steps

Outlines initial checks for wiring, parallel connections, and control voltage.

Locating Breaks or Shorts

Guides on determining if a break or short exists under the floor after installation.

Identifying Conductor Faults

Explains how to detect breaks (infinity Ohm reading) and shorts (conductor-sheath continuity).

Important General Considerations

Critical Heating Element Integrity Rules

Lists crucial rules for maintaining the integrity of the heating element.