4
Never disconnect the plug to stop compressor, set the switch knob to the OFF
position.
If the release valve doesn’t work when motor stopped, find the cause immediately so
as not to damage motor.
Lubricating oil must be clean, oil level should be kept in red circle of the oil leveler.
Before restarting the motor press the reset button and check the air
compressor carefully, check the pressure in the air tank and make sure it is under 0.8Mpa.
Always disconnect the plug to cut off power supply and open the outlet valve and
discharge all air in the air tank after use.
6. MAINTENANCE
Before maintenance operation, stop the air compressor, cut off power supply and
discharge all air in the air tank.
Clean crank case and renew lubricating oil after the first 10 working hours.
Check the oil level after every 20 working hours,
and replenish if necessary (Fig.5).
Clean crank case and renew the oil, clean air
filter every three months.
Open the drain cock under the tank to exhaust
the condensation after every 60 working hours but
less than every 7 days.
Check the safety valve and pressure gauge by
professional organization every 6 months and make
sure they are in correct condition.
Make sure there is no rust on the air tank and the air tank is not damaged.
Check the thickness of the air tank by professional organization every year and
make sure the thickness is not less than 2.1mm.