Questions and Answers

  • M
    Michele RobinsonAug 8, 2025
    What to do if the chemical feeder runs continuously on my Water Maze CLP-5024 Water Dispenser?
    • K
      Kim AtkinsonAug 8, 2025
      To resolve a chemical feeder running continuously on your Water Maze Water Dispenser: * Ensure that the AUTO feed mode is selected. * Verify that the chemical feeders are properly connected to their respective connectors or controller unit.
  • M
    Martin JacksonAug 12, 2025
    Why are pH or ORP readings inconsistent or slow on my Water Maze CLP-5024?
    • N
      Natalie DeanAug 12, 2025
      For inconsistent or slow pH or ORP readings on your Water Maze Water Dispenser: * Verify that the sensor cables are properly connected to their respective BNC connectors and the controller unit. * Clean or replace the sensor as outlined in the maintenance section. * If needed, replace the sensors.
  • H
    haleymelissaAug 16, 2025
    How to fix pH requiring frequent calibration on Water Maze CLP-5024 Water Dispenser?
    • R
      Ryan WilsonAug 16, 2025
      If the pH requires frequent calibration on your Water Maze Water Dispenser, clean or replace the sensor as outlined in the maintenance section.
  • C
    Cynthia EvansAug 21, 2025
    What to do if the ORP feeder does not activate on my Water Maze CLP-5024?
    • L
      Lisa MorrisAug 21, 2025
      To troubleshoot an ORP feeder that does not activate on your Water Maze Water Dispenser: * Make sure the AUTO feed light for ORP is on. * Check the ORP setpoint. * Check ORP relay fuse (5A slow blow) marked F2 on control board.
  • A
    Anthony WatkinsAug 25, 2025
    What to do if the pH feeder does not activate on my Water Maze CLP-5024?
    • L
      Luke BarnettAug 26, 2025
      To troubleshoot a pH feeder that does not activate on your Water Maze Water Dispenser: * Verify that the acid/base feed jumper JP14 on the control board is properly set. * Make sure the AUTO feed light for pH is on. * Check the pH relay fuse (5A slow blow) marked F2 on control board.
  • A
    Adrian WellsAug 29, 2025
    Why are pH and ORP values illogical on my Water Maze CLP-5024?
    • P
      Patrick FarmerAug 29, 2025
      If you're seeing illogical pH and ORP value displays on your Water Maze Water Dispenser, the sensor cable connections may be reversed. Verify that the sensor cables are properly connected to their respective BNC connectors on the controller unit.
  • A
    Ashley BarnesSep 2, 2025
    How to fix no lights on Water Maze CLP-5024 with power on?
    • M
      Michael DavisSep 2, 2025
      To troubleshoot the issue of no lights being on with power on for your Water Maze Water Dispenser: * Check for power going to the controller. * Check for a damaged power connector. * Check the internal fuse (1A slow blo) marked F3 on the control board.