EasyManua.ls Logo

Water Right ECLIPSE WRO-35 - User Manual

Water Right ECLIPSE WRO-35
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Tested and Certifi ed by NSF International against
NSF/ANSI Standard 58 for the reduction of the claims
specifi ed on the Performance Data Sheet.
ECLIPSE
Reverse Osmosis
Drinking Water Sys tem
from Water-Right
Sold and serviced
by authorized
Water-Right dealers.
Installation, Operation & Service Manual
WRO-35
R.O. Drinking
Water System

Questions and Answers

  • A
    Ashley JeffersonAug 20, 2025
    What to do if there is high Total Dissolved Solids (TDS) in Water Right Water System product water?
    • D
      David LandryAug 20, 2025
      If you're noticing high Total Dissolved Solids (TDS) in the product water of your Water Right Water System, several factors could be contributing. Ensure that the product water and drain water lines are not reversed by checking and correcting the plumbing. A clogged drain restrictor or a plugged drain orifice in the dispensing faucet can also cause this issue; clear or replace these components as needed. If the ASO valve is not closing properly, it should be repaired or its components replaced. A new activated carbon module or in-line post filter that hasn't been completely rinsed can also elevate TDS levels; flush the system with several full tanks of product water. Finally, an increase in the feed water TDS will naturally lead to a corresponding increase in the product water TDS.
  • M
    Mr. Anthony Campbell Jr.Aug 22, 2025
    How to eliminate tastes and odors in Water Right Water System product water?
    • A
      awelchAug 22, 2025
      If your Water Right Water System's product water has unpleasant tastes and odors, it could be due to a few reasons. The activated carbon module or in-line post filter may be exhausted and need replacement. Foreign matter in the holding tank can also cause this issue; clean, flush, and sanitize the system, and replace the filters. Ensure the product water and drain water lines are correctly plumbed, as reversed lines can introduce contaminants. Dissolved gasses in the feed water may also contribute to the problem, requiring pretreatment of the feed water to remove these gasses. An increase in product water TDS may also cause tastes and odors.
  • E
    Eric ShermanAug 30, 2025
    What to do if drain water overflows at the Water Right Water System dispensing faucet?
    • B
      Brittney GrayAug 30, 2025
      If drain water is overflowing at the dispensing faucet of your Water Right Water System, several issues could be the cause. Check for a blocked air gap and clear it. Inspect the drain tubing for clogs and clear any obstructions. Ensure the drain clamp hole is properly aligned with the hole in the drain pipe. If the drain flow rate is excessive, consider replacing the drain restrictor.
  • G
    Gregory MitchellSep 1, 2025
    Why is the amber light on the Water Right Water System Water Quality Monitor on?
    • C
      Christine RobinsonSep 1, 2025
      If the amber light is illuminated on your Water Right Water System's Water Quality Monitor, it could indicate a couple of issues. If the system hasn't been used for an extended period, empty the storage tank, wait 15 minutes while the system makes water, and then test the water quality again. Alternatively, the filters may be plugged, or the membrane may be fouled or exhausted, requiring replacement of the filters and/or membrane.
  • R
    Regina WaltonSep 5, 2025
    How to fix high total dissolved solids (TDS) in the product water of my Water Right Water Filtration Systems?
    • L
      Lisa ShermanSep 5, 2025
      If you're experiencing high Total Dissolved Solids (TDS) in the product water, consider the following: * The Sediment/Carbon Module or Activated Carbon Module may be clogged. Replace the Modules. * Low Water Pressure: Feed Water Pressure must be above 40 psig. * Check Feed Water Saddle Valve. * The R.O. Membrane O–ring may be crimped. Check the O–ring. * The R.O. Membrane brine seal may not be sealing up into the manifold head. Check the brine seal. * The R.O. Membrane may be expended. If Membrane life is unusually short, find and correct the problem. Replace Membrane.
  • B
    Brian MorganSep 7, 2025
    What causes tastes and odors in the product water from my Water Right ECLIPSE WRO-35 and how to fix it?
    • E
      Edward ReynoldsSep 7, 2025
      Tastes and odors in the product water can arise from several issues: * The Activated Carbon Post Filter may be exhausted. Replace the Filter. * There may be foreign matter in the Holding Tank. Clean, flush, and sanitize the system, and replace the filters. * The Product Water and Drain Water lines may be reversed. Correct the plumbing. * Dissolved gasses may be present in the Feed Water. Pretreat Feed Water to remove dissolved gasses. * There may be an Increase in Product Water TDS. See high TDS in the Product Water section.
  • A
    Ashlee CarrilloSep 9, 2025
    What to do if I see drain water overflowing at the air gap faucet of my Water Right Water Filtration Systems?
    • B
      Barry ValenzuelaSep 9, 2025
      If drain water is overflowing at the Air Gap Faucet, here are some possible causes and solutions: * The Air Gap may be blocked. Clear the Air Gap. * Rinse with vinegar for removal of calcium buildup. * The drain tubing may be clogged. Clear the tubing. * The Drain Clamp hole may be misaligned. Align it with the hole in the drain pipe. * There may be an excessive drain flow rate. Replace the Drain Restrictor.
  • N
    Nicole GraySep 12, 2025
    How to resolve high total dissolved solids (TDS) in the product water (continued) of my Water Right ECLIPSE WRO-35 Water Filtration Systems?
    • A
      Angela JamesSep 12, 2025
      To address continued high Total Dissolved Solids (TDS) in the product water: * The Product Water and Drain Water lines may be reversed. Correct the plumbing. * If there's no drain flow, the Drain Restrictor may be clogged. Clear or replace the Drain Restrictor. * If there's no drain flow, the drain orifice in the Air Gap Faucet may be plugged. Clear or replace the Air Gap Faucet. * The ASO Valve may not be closing. Repair or replace the ASO Valve Components. * A new Activated Carbon Post Filter may not be rinsed completely. Flush with several full tanks of Product Water. * The Feed Water TDS may have increased. An increase in Feed Water TDS will give a corresponding increase in Product Water TDS.
  • W
    wayne74Sep 13, 2025
    What causes faucet leaks or drips in Water Right ECLIPSE WRO-35 and how can I fix them?
    • J
      james37Sep 13, 2025
      If your faucet is leaking or dripping, here are some potential causes and solutions: * Leaks from the spout can be adjusted by turning the tee bar just below the handle to provide a small amount of free play in the handle when shut off. * If there are leaks from the base of the delivery tube, the O–ring is likely bad; replace the O–ring. * If there are leaks from beneath the handle, the O–rings are likely bad. Repair or replace the faucet. * O–rings are bad, repair or replace faucet.
  • M
    Matthew KingSep 15, 2025
    What does it mean if the amber light is on on my Water Quality Monitor of my Water Right ECLIPSE WRO-35, and what should I do?
    • M
      Michael OconnorSep 15, 2025
      If the amber light is illuminated on your Water Quality Monitor, it could indicate: * The system has not been used for an extended period. Empty the storage tank, wait 15 minutes (while the system is making water), and test the water quality again. * The filters are plugged, or the membrane is fouled or exhausted. Replace the filters and/or membrane.

Summary

Introduction to the Eclipse R.O. System

System Specifications and Performance

Preparation for Installation

Major System Components Overview

Lists essential R.O. system parts for user identification and confirmation.

Recommended Tools for Installation

Lists necessary tools for a safe and effective installation of the R.O. system.

Site Selection Criteria for Components

Guides optimal placement of system components for functionality, access, and protection.

Installation Steps for the R.O. System

Faucet and Water Quality Monitor Installation

Details installing the dispensing faucet and its integrated water quality monitor.

Feed Water Saddle Valve Installation

Instructions for connecting the system to the main water supply using a saddle valve.

Drain Clamp Installation Procedure

Guidance on attaching the drain clamp to the sink drain pipe for wastewater removal.

R.O. Manifold Assembly Installation

Steps for mounting and connecting the central manifold that houses filter cartridges.

Holding Tank Placement and Hose Connections

Instructions for placing the storage tank and connecting all necessary tubing for water flow.

System Start Up and Sanitization

Procedures for initial system startup, module installation, and sanitization.

Operation and Maintenance Guidelines

Normal Operation and Water Quality Monitoring

Explains daily system function, tank refilling, and water quality checks.

Filter Module Replacement Procedure

Provides guide on recommended intervals and procedures for replacing filter cartridges.

Replacing the In-Line Activated Carbon Post Filter

Details the process for replacing the final carbon filter for taste and odor.

Technical Data and Performance Metrics

Water Quality Measurement Parameters

Explains how water quality is measured using TDS and conductivity.

Water Quantity Metrics Explained

Defines terms like Flux, Product Water Rate, and Reject Ratio for system performance.

Net Pressure Differential Explanation

Describes pressure dynamics across the RO membrane affecting performance.

Water Production Rate Chart

Table showing estimated water output based on feed water conditions.

Troubleshooting Guide

Exploded View and Parts List

Water Right ECLIPSE WRO-35 Specifications

General IconGeneral
ModelECLIPSE WRO-35
CategoryWater Filtration Systems
TypeReverse Osmosis
Stages5
Gallons Per Day (GPD)35
Daily Production35 gallons
Filter Life6-12 months