INSTALLATION
UNPACKING AND INSPECTION
When the equipment is received, all items should be carefully checked against the packing list to ensure all cartons
have been received. Move units in the normal "up" orientation as indicated by the arrows on each carton. Examine
cartons for shipping damage, removing the units from the cartons if necessary. If the unit is damaged, the carrier
should make the proper notation on the delivery receipt acknowledging the damage.
SAFETY CONSIDERATIONS
VERY IMPORTANT: Never install your air conditioner in the bilge or engine room areas. Ensure that the selected
location is sealed from direct access to bilge and/or engine room vapors. Do not terminate condensate drain line
within three 3’ (914mm) of any outlet of engine, generator exhaust system, compartment housing an engine or
generator, or in a bilge, unless the drain is connected properly to a sealed condensate or shower sump pump. Seal
all cabin sole penetrations around condensate hoses to eliminate harmful bilge fumes in the cabin living spaces.
Installation and servicing of this system can be hazardous due to system pressure and electrical components.
When working on this equipment, always observe precautions described in the literature, tags and labels attached
to the unit. Follow all safety precautions. Wear safety glasses and work gloves and place a fire extinguisher close
to the work area. The following is a summary of the labels on the unit:
Indicates an imminently hazardous situation which, if not avoided, will result in death or
serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury.
Special note. Make sure to read before proceeding.
Electrical shock hazard. Disconnect voltage at main panel or power source before
opening any cover. Failure to comply may result in injury or death.
This unit cannot and should not be mounted in spaces containing gasoline engines,
tanks, LPG/CPG cylinders, regulators, valves or fuel line fittings. Failure to follow this
warning could result in injury or death and violation of federal requirements for ignition
protection.
Notice this component is charged with Hydro chlorofluorocarbon (H CFC) refrigerant R22. Effective
July 1, 1992, it shall be unlawful for any person to knowingly vent or otherwise knowingly release
any class 1 (CFC) or class 2 (H CFC) substance as a refrigerant in a manner which permits such
substance to enter the atmosphere per the clean air act of 1990. Public law 101-549 title IV section
608-c. Failure to comply may result in severe penalties, including fines and imprisonment.
To minimize the hazard of electrical shock, this component must be effectively grounded.
High compressor temperature is normal. Do not touch.