SERVICE INFORMATION
Repair manual CF 2 + CF 3
Use a drift punch to drive / knock the bearing out
of the eccentric housing.
Clamp the eccentric shaft into a vise and remove
the inner bearing ring (1).
Remove the shaft seal ring from the housing cover
(from the inside out).
Remove the O-ring from the housing cover.