Page #1 background image
Note - Figures in these instructions are intended to
represent all Genesis Gas Barbecue models, your
barbecue may differ from these illustrations.
Your Weber
®
Genesis
®
Gas Barbecue, as well as any
outdoor gas appliance, is a target for spiders and other
insects. They can nest in the venturi section of the
burner tubes. This blocks the normal gas flow, and can
cause the gas to flow back out of the air shutter.
Figure 1. This could result in a fire in and around the air
shutters, under the control panel, causing serious
damage to your barbecue. We have developed the
Weber Spider Stopper Guards to significantly
reduce the chance of this happening to your Weber
Genesis Gas Barbecue.
The Weber Spider Stopper Guard fits tightly around the
air shutter section of the burner tube and the valve,
thereby preventing spiders and other insects access to
the burner tubes through the air shutter openings.
Figure 2.
Figure 2
Weber Spider
Stopper Guard
Figure 1
Air shutter
Venturi
®
®
Weber
®
Spider Stopper
Guards
Installation Instructions
We recommend that you inspect the Weber Spider
Stopper Guards at least once a year. Also inspect and
clean the Spider Stopper Guards if any of the
following symptoms should ever occur.
1. The smell of gas in conjunction with the burner
flames appearing yellow and lazy.
2. Barbecue does not reach temperature.
3. Barbecue heats unevenly.
4. One or more of the burners do not ignite.
WARNING: Make sure gas supply is turned off; i.e.:
LP cylinder valve is closed or natural gas supply
shut-off turned off and hose disconnected from the
Quick Disconnect.
Note - You should inspect the burners for spider webs
and other obstructions before installing your new
Weber Spider Stopper Guards. To inspect the burners,
you must remove the manifold. The following
instructions show you how to both remove the manifold
and install the Weber Spider Stopper Guards.
Step 1
For LP units only, disconnect the gas hose from the LP
tank.
Step 2
Pull off all burner control knobs. Remove control panel.
Step 3
Remove the igniter.
DANGER
Failure to correct these symptoms may
result in a fire which can cause serious
bodily injury or death, and cause damage
to property.
For Genesis 1, 2, 3, 4, 5 and Perma-Mount Gas Barbecues
27-39900 Rev. 3/90
Question and Answer IconNeed help?

Do you have a question about the Weber Spider Stopper Guards and is the answer not in the manual?

Weber Spider Stopper Guards Specifications

General IconGeneral
CategoryLawn and Garden Equipment
MaterialStainless Steel
TypeGrill Accessory
FunctionPrevents spiders and insects from nesting in burner tubes
InstallationEasy to install
Package Contentsspider stopper guards

Summary

Weber Spider Stopper Guards Installation

Problem and Solution Overview

Explains how spiders can block gas flow and cause fires, introducing Spider Stopper Guards as a solution.

Safety Warnings and Dangers

Highlights dangers of gas leaks and fire, with critical warnings about gas supply and potential injury.

Step 1: Disconnect Gas Hose (LP Units)

Instructions for LP units to disconnect the gas hose from the LP tank as a safety precaution.

Step 2: Remove Control Panel

Guide to removing burner control knobs and the control panel for access.

Step 3: Remove Igniter

Procedure to remove the igniter unit from the barbecue.

Step 4: Disconnect Capillary Tube/Side Burner Hose

Instructions for disconnecting capillary tubes on FlameCheck systems or side burner hoses.

Step 5: Remove Manifold Bracket

Guidance on removing the manifold bracket, manifold, and cooking box as a unit.

Step 6: Remove Manifold

Procedure for unscrewing thumb screws and carefully removing the manifold.

Step 7: Inspect Burners

Use a flashlight to look inside each burner for obstructions.

Step 8: Clean Burner Tubes

Use a tool or wire to clean burner tubes of any obstructions.

Step 9: Install Manifold

Insert valves into burner tubes and install manifold thumb screws, ensuring proper alignment.

Step 10: Install Manifold Bracket

Hook the bracket onto the manifold and then onto the frame brace.

Step 11: Check Air Shutter Openings

Ensure air shutters are open approximately 1/8 to 3/16 of an inch.

Step 12: Reconnect Hoses/Capillary Tube

Reconnect side burner hoses or capillary tubes to FlameCheck valve.

Step 13: Reinstall Igniter

Procedure to reinstall the igniter after installation.

Step 14: Install Spider Stopper Guards

Fit guards around burner tubes and valves, ensuring latching.

Step 15: Check Guard Fit

Rotate guards to align seams with Venturi fins, ensuring no gaps.

Step 16: Check for Gas Leaks

Crucial safety step to check all connections for leaks without open flames.

Step 17: Reinstall Control Panel

Install burner control knobs and the control panel.

Inspection and Cleaning of Weber Spider Stopper Guards

Regular Inspection and Cleaning