Installation and Startup Guide
This document covers the installation of cMT-SVRX Series, for the detailed specifications and operation,
please refer to Datasheet, Brochure and EasyBuilder Pro User Manual. Please read all warnings,
precautions, and instructions on the device carefully before use.
Install Environment:
Electrical
Environment
The HMI product has been tested to conform to European CE requirements. This
means that the circuitry is designed to resist the effects of electrical noise. This
does not guarantee noise immunity in severe cases. Proper wire routing and
grounding will insure proper operation.
Environmental
Considerations
(1) Make sure that the units are installed correctly and that the operating limits
are followed. Avoid installing units in environments where severe
mechanical vibration or shocks are present.
(2) Do not operate the unit in areas subject to explosion hazards due to
flammable gases, vapors or dusts.
(3) Do not install the unit where acid gas, such as SO2 exists.
(4) This device should be mounted in the vertical position and for use on the flat
surface enclosure.
(5) For use in Pollution Degree 2 Environment and dry location.
(6) Relative Humidity: 10% ~ 90% (non-condensing)
Cleaning
Considerations
Clean the device using dry cloths. Do not use liquid or spray detergents for
cleaning.
IP rating
IP 20
Warning
Protection impairment if used in a manner not specified by the manufacturer.
ficit de protection si utilisé d'une manière non spécifiée par le fabricant.
Unpacking the Unit
Unpack and check the delivery. If damage is found, notify the supplier.
NOTE: Place the unit on a stable surface during installation. Dropping it or letting it fall may cause
damage.
(1) Installation Instruction, A4 double sided *1
(2) Power Connector *1
(3) cMT-SVRX *1
Installation Instructions
Rail mounting: DIN rail 35mm
Panel mounting: Use two M4 or #8 panhead screws, mounting hole size is 4.6mm
Plan for adequate space around the unit and inside the enclosure, for ventilation and cables. Consider the
heat from other devices inside the enclosure. The ambient temperature around the unit must be 0 ~ 50°C.
The aluminum flat-sheet at the back of the unit is a heat sink. Please be careful not to touch the heat sink
since its heat can rise to 70°C in maximum when the unit is running. Planning for a 3cm space between the
unit and other devices is recommended.
Power Connections
Power Connector Specifications:
Wire AWG: 24~12
Wiring Conductor Minimum Temperature: 75°C
Screw Torque: 4.5 lbf-in (max.)
Copper conduct only.
Scifications du connecteur d'alimentation:
AWG de fil: 24 ~ 12
Température minimale du conducteur de câblage: 75°C
Couple de vis: 4.5 lbf-in (max.)
Conducteur en cuivre seulement
NOTE: Connect positive DC line to the ‘+’ terminal and the DC
ground to the ‘- terminal.
System Settings
Connect cMT-SVRX with a router using a RJ-45 cable, launch EasyBuilder Pro on your computer, open
Download window to find this cMT-SVRX.
After connecting cMT-SVRX successfully, enter the IP address of this cMT-SVRX in the browser to open
the System Settings page, and then enter the default password “111111” to log in and configure cMT-SVRX.
cMT-SVRX series
Installation Instruction
3
5
4
1
2
Question and Answer IconNeed help?

Do you have a question about the weintek cMT-SVRX Series and is the answer not in the manual?

weintek cMT-SVRX Series Specifications

General IconGeneral
ModelcMT-SVRX Series
RAM1GB
Power Supply / Input24V DC
Humidity10% to 90% non-condensing
Protocols SupportedMQTT, Modbus TCP/RTU

Summary

Installation and Startup Guide

Install Environment

Details environmental requirements for unit installation, including electrical and general considerations.

Environmental Considerations

Lists precautions for operating the unit in specific environments like hazardous areas or near gases.

Cleaning Considerations

Provides instructions on how to clean the device using dry cloths and avoiding liquid detergents.

IP Rating Information

Specifies the Ingress Protection rating (IP20) and warns about protection impairment if misused.

Installation Instructions

Mounting Methods

Covers rail mounting (DIN rail 35mm) and panel mounting using M4 or #8 screws.

Ventilation and Heat Management

Emphasizes planning space for ventilation and notes the heat sink temperature.

Power Connections

Power Connector Specifications

Lists specifications for the power connector, including wire gauge, temperature, and torque.

EasyBuilder Pro Software Settings

Project File Download

Instructions on launching EasyBuilder Pro and downloading a project file to the CMT-SVRX.

Communication Connection

RS485 Communication Support

Notes that COM2 and COM3 [RS485] support MPI 187.5K, usable one at a time.

DIP SW Settings

Details how DIP switches SW1 and SW2 control IP settings and OS updates.

Safety Precautions

General Electrical Safety

Emphasizes meeting electrical standards and using SELV-compliant power supplies.

Power and Fusing Requirements

Covers power LED behavior, resettable fuses for overcurrent protection, and isolation.

Emergency Stop and Wiring

Mandates an EMERGENCY STOP and provides detailed wiring guidelines for safety.

Hardware and Programming Considerations

Highlights system designer awareness of potential failures and safety measures in control systems.

Battery Replacement

Battery Specification and Handling

Specifies battery type (CR1220), voltage, and requires qualified personnel for replacement.