Installation and operating instruction
Combustion manager W-FM 100 und W-FM 200
83054802 1/2018-07

Table of Contents

Questions and Answers

  • D
    Daniel DixonAug 3, 2025
    How to reset Weishaupt W-FM 100 burner after a fault?
    • B
      Barbara Roy MDAug 3, 2025
      To reset the burner after a fault, press the reset key. The burner should then be reset.
  • Z
    zlopezAug 16, 2025
    What to do if the ABE displays a fault in Weishaupt W-FM 100?
    • M
      Mr. Anthony MartinezAug 16, 2025
      If the ABE displays a fault, try the following: * Exit the display using the [esc] key. * Reset the burner using the [ENTER] key. If the [esc] key has been pressed twice, the reset can only be carried out via the menu. To do this: 1. Select 'Operating display'. 2. Select 'Status/Reset'. The current lockout will be displayed. You can then exit the display using the [esc] key and reset the burner using the [ENTER] key.

Summary

2 Safety

2.1 When gas can be smelled

Immediate actions to take when gas is detected.

3 Product description

4 Installation

5 Installation

5.1 Electrical connection

Instructions for connecting the combustion manager, including safety warnings.

6 Operation

6.10 O2 controller

Covers the O2 controller functionality for modulating burners with O2 module.

6.11 CO monitor and CO controller

Covers the CO monitor and CO controller functions, requiring O2 trim.

6.12 Load controller

Describes the PID load controller functionality.

6.15 Flue Gas Recirculation

Covers the FGR function, its modes, and settings.

7 Commissioning

7.2 Adjusting the burner

Covers burner adjustment procedures.

7.3 Load controller

Describes configuring the load controller.

7.4 O2 controller

Covers setting O2 monitor and defining fuel type.

7.5 CO controller

Covers setting the measurement amplifier LT3 and CO control parameters.

7.6 Flue gas recirculation (temperature compensated)

Guides on adjusting FGR for temperature compensation.

7.9 Check combustion

Covers determining excess air, flue gas temperature, and flue gas losses.

8 Servicing

9 Troubleshooting

9.1 Procedures for fault conditions

Covers checking prerequisites and handling faults/lockouts.

9.2 Fault

Describes fault occurrences, shutdown behavior, and accessing fault history.

9.3 Lockout

Explains lockout conditions, display, and reset procedures.

Weishaupt W-FM 100 Specifications

General IconGeneral
BrandWeishaupt
ModelW-FM 100
CategoryController
LanguageEnglish