10
It is strictly to pay attention that water does not get into the motor.
After an interruption of work first see for yourself that the core bit turns loosely before you start the
machine again.
Wear ear protection when working with this machine.
Wear work gloves when using the core drill. Gearbox, motor and handle become hot during operation.
3. T E C H N I C A L D E S C R I P T I O N
The DKS15 is a dry core drilling machine, which is operated without water supply. It can be used both
in a drill stand and as a hand-held core drilling machine.
The switch-on and switch-off soft-beat function accelerates work progress in reinforced concrete and
hard materials. The drilling dust is removed from the diamond segments by the soft beat and removed
by the efficient dust extraction system.
DKS15SP refers to core drills with a D-handle instead of a pistol grip.
The boring tool (4) consists of a tube with an appropriate tool adapter 1 1/4" UNC, and with soldered-
on or welded-on diamond segments.
The machine may not be used for a different purpose or with a different tool.
3.1 Technical Data
Type DKS15 DKS15 L DKS15 S
Rated Voltage V 230 230 230
Rated Current A 9,3 9,3 9,3
Power input W 2000 2000 2000
Power output W 1340 1340 1340
Frequency Hz 50 - 60 50 - 60 50 - 60
Rated Speeds (Rated Load) 1/min 700 / 1700 540 / 1200 900 / 1700
Beat frequency 1/min 14000 / 34000 10800 / 24000 16200 / 30600
Beat energy Joule
0,4
0,1
0,5
0,2
0,3
0,2
Drilling i drill rig/ concrete mm 30-150 40-180 30-100
Drilling i hand-held/
concrete
mm 30-100 40-120 30-100
Drilling i hand-held/
masonry
mm 30-180 40-200 30-120
Weight kg 5 5 5
Tool fixture 1 1/4" UNC
3.2 List of contents
Diamond core drill (1), with adapter for dust extraction (3), carrying case and instructions manual.
Special accessories: Elastic bore piercer
3.3 Sound emission and vibration acceleration
Sound emission values determined according to EN 60745-2-1.
The typical A-weighted sound pressure level is 88 dB(A).
The typical A-weighted sound capacity level is 99 dB(A).
Uncertainty K =3 dB.
h
Vibration total values a (triax vector sum) and uncertainty K determined according to EN 60745-2-1:
h,DD
Drilling into concrete: a = 5 m/s , K=1,5 m/s .