EasyManua.ls Logo

WERTHER INTERNATIONAL PC120-4C User Manual

WERTHER INTERNATIONAL PC120-4C
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Compressore silenzioso automatico
AUTOMATIC SILENT COMPRESSOR
COMPRESSEUR SILENCIEUX AUTOMATIQUE
AUTOMATISCHE LEISELAUFKOMPRESSOR
COMPRESSORE SILENCIOSO AUTOMATICO
PC120-4C
Costruttore - Manufacturer - Manufacturer
Hersteller - Fabricante
WERTHER INTERNATIONAL Inc.
8614 Veterans Memorial Drive
Houston, TX 77088 - USA
Phone 832-327-9378
E-MAIL info@werther.com
WEB www.werther.com
Centro di assistenza autorizzato
Authorized service center
Centre technique agréé
Zugelassenes Kundendienstzentrum
Centro de asistencia autorizado
GTEK AUTOMATION 26212 Dimension Drive, Suite 150 Lake Forest, CA 92630 Ph. 949-680-4242 www.gtek-automation.com
Question and Answer IconNeed help?

Do you have a question about the WERTHER INTERNATIONAL PC120-4C and is the answer not in the manual?

WERTHER INTERNATIONAL PC120-4C Specifications

General IconGeneral
BrandWERTHER INTERNATIONAL
ModelPC120-4C
CategoryAir Compressor
LanguageEnglish

Summary

General Information

Importance and Use of the Manual

This manual is an integral part of the compressor and must accompany it. Users must know instructions before use.

Content

Lists the items included in the packing: the compressor and the instruction manual.

Storage

Compressors must be kept in a dry, covered, and sheltered place between -10°C and +40°C.

Weights and Dimensions

Provides gross weights and packing dimensions for the compressor model.

Packing Disposal

Packing material must be disposed of according to local regulations for recycling or reuse.

Lifting

Compressors require careful handling and positioning using appropriate equipment like fork-lift trucks.

Safety

Covers general safety precautions, including proper use, environmental protection, and avoiding tampering with safety valves.

Operation

Machine Set Up

Install the compressor on a flat, well-ventilated surface, ensuring correct power supply voltage and socket type.

Operating Instructions

Details how to start the compressor, its automatic working process, and pressure adjustment using the reducer-filter.

Filling Up

Provides tank filling times for different voltage/frequency configurations at 0 to 7 bar.

Check of Filling Time

Outlines steps to check compressor filling time, including emptying the tank and verifying connections for leaks.

Troubleshooting

The compressor does not start

Lists potential causes for the compressor failing to start, such as power issues, electrical faults, or pressure switch problems.

The compressor does not reach the maximum pressure

Addresses issues where the compressor fails to build sufficient pressure, possibly due to air leaks or clogged valves.

The compressor works, but pressure does not increase in tank (or increase too slowly)

Identifies causes for slow pressure build-up, such as a clogged air filter or leaks.

The compressor works but does not load

Suggests defects like valve or gasket breaks as reasons for the compressor not loading.

The compressor stops while working

Explains that the motor has thermal protection, causing stops when overheating, with automatic restart after cooling.

Air leaks

Highlights air leaks from connections as a potential cause for various operational problems.

Leak from the valve placed under the pressure switch

Addresses leaks from the valve under the pressure switch, indicating possible valve damage or seal issues.

The compressor starts when no air is being tapped

Points to air leaks as the cause for the compressor starting unnecessarily when no air is drawn.

The compressor starts and stops more frequently than usual

Suggests condensate build-up or air leaks as reasons for frequent start/stop cycles.

The compressor does not switch on when pressure is under the minimum level and/or does not switch off at max pressure

Attributes failure to switch on/off at set pressures to a defective pressure switch.

The compressor gets very hot

Explains that high temperature can be due to air leaks, clogged filters, high ambient temperature, or incorrect model selection.

Special Informations

Compressor Demolition

Safety regulations must be observed during demolition; metal parts are recyclable, others require disposal according to laws.

Spares

Defective parts must be replaced by authorized personnel, adhering to safety regulations.

Warranty

Covers a 12-month guarantee for free replacement of defective parts, excluding electric/worn parts and labour costs.

Periodic Maintenance

Related product manuals