Operating Instructions
Model 39300 and 39301
Hydrostatic Test Pump
June 2013
Dimension
14” ( 5.5cm)L x 10” (3.9cm)W x 12” (4.7cm)H
Weight
35lbs; 16kg
Capacity
4gpm / 15lpm, @60hz; 3.4gpm / 12lpm @ 50hz
Pressure
0 - 300psi (20 bar)
Motor
1/2hp 115/230V, 1725rpm @60hz, 1450rpm@50hz
Lubrication
Chassis Grease
Control
Adjustable pressure relief valve
Gauge
Glycerin filled, 0 - 600psi (40bar)
Inlet Connection
3/4” Female garden hose
Outlet Connection
9/16 - 18 JICF Male
Pump Style
Twin piston, positive displacement
Discharge Hose
1/4” NPT Male x 1-’ (3m), 4000psi (266 bar)
Hose Ends
9/16 - 18 JICF Female swivel x 1/4” Male NPT
Pressure Feed Method: (Preferred Method #1)
This is typically a residential water source with about 40 to 60 psi
1. Fill the water line (or test vessel) to be tested prior to pump connection.
2. Connect water supply hose to the garden hose inlet € connection on the pump.
3. Open valve and turn supply water on.
4. Purge the pump and pressure hose of all air.
5. Connect output (pressure) hose between pump (B) and water line (or vessel) being
tested. (Water line or test vessel should be pre-filled with water before the test pump
is attached.)
6. Turn pump on and purge water line (or vessel) of all air at the highest point of the
system. Close valve once air has been purged.
7. With pump running, bring water line (or vessel) to pressure.
8.
Watch the gauge (A) while pumping. As you reach the desired pressure; turn the
valve (C) to the ‘off’ position. Motor can now be turned off. If pressure drops off,
there is a leak in the line.
Gravity Feed Method: (Preferred Method #2)
This method requires a tank with a water outlet at the bottom. The water tank’s outlet
Should be lever with or above the level of the water inlet connection on the pump. This
allows water to flow naturally into the test pump. Follow the “Pressure Feed Method” s
steps 1 through 8 (listed above).
Question and Answer IconNeed help?

Do you have a question about the Wheeler-Rex 39300 and is the answer not in the manual?

Wheeler-Rex 39300 Specifications

General IconGeneral
BrandWheeler-Rex
Model39300
CategoryWater Pump
LanguageEnglish

Summary

Pump Specifications

Operating Methods

Pressure Feed Method

Step-by-step guide for hydrostatic testing using a water source.

Gravity Feed Method

Procedure for hydrostatic testing using a water tank with bottom outlet.

Pump Operation Procedures

Siphon Method

Instructions for using a clean water source via siphoning.

Pre-Setting Your Pump

Guide to adjusting the pressure relief valve for specific pressure settings.

Pump Support

Troubleshooting Your Pump

Common issues and solutions for pressure not being reached or check valve problems.

Pump Maintenance

Routine care for the pump, including lubrication and winterizing.

Parts and Diagrams

Pump Assembly Parts List

Detailed list of components for the pump assembly with part numbers.

39300 Test Pump Parts

Itemized parts list for the 39300 model, including electrical components.

Switch Wire Diagram

Diagram illustrating the wiring connections for the pump's switch.

Product Information and Safety

Limited Lifetime Warranty

Details of the Wheeler-Rex product warranty, coverage, and limitations.

General Tool Operation Warnings

Essential safety precautions for operating power tools.