PRODUCT MODEL NUMBERS
GXW7330DX GXW7336DX
ELECTRICAL REQUIREMENTS
• A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical circuit is required.
VENTING REQUIREMENTS
This canopy hood is factory set for venting through the roof or wall.
A 6" (15.2 cm) round vent system is needed for installation (not included). The
hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and
air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent through a
wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters)
for each vent piece used in the system.
30" (76.2 CM) AND 36" (91.4 CM) Wall-Mount Canopy Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10320580A
9/20/10
®
Roof Venting Wall Venting
A. Roof cap
B. 6" (15.2 cm)
round vent
A. Wall cap
B. 6" (15.2 cm)
round vent
A
A
B
B
Example vent system
The following example falls within the maximum recommended vent
length of 35 ft (10.7 m).
LOCATION REQUIREMENTS
Have a qualified technician install the range hood. It is the installer's
responsibility to comply with installation clearances specified on the
model/serial rating plate. The model/serial rating plate is located behind
the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas, such as
windows, doors and strong heating vents.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured
Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly
the Federal Standard for Mobile Home Construction and Safety, Title 24,
HUD, Part 280) or when such standard is not applicable, the standard
for Manufactured Home Installation 1982 (Manufactured Home Sites,
Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or
with local codes.
PRODUCT DIMENSIONS
Vent Piece 6" (15.2 cm) Round
45° elbow 2.5 ft (0.8 m)
90° elbow 5.0 ft (1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
Length of system = 13.0 ft (3.9 m)
90 elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
30" (76.2 cm) or
36" (91.4 cm)
20" (50.8 cm)
14¹⁄₈"
(35.9 cm)
7¹⁄₈"
(18.1 cm)
8¹⁄₁₆"
(20.5 cm)
28⁷⁄₈" (73.3 cm) min.
38¹⁄₄" (97.2 cm) max.
1"
(4.0 cm)
10"
(25.4 cm)
Page 1 of 2
Question and Answer IconNeed help?

Do you have a question about the Whirlpool GXW7330DX and is the answer not in the manual?

Whirlpool GXW7330DX Specifications

General IconGeneral
BrandWhirlpool
ModelGXW7330DX
TypeUndercabinet
AirflowUp to 400 CFM
CFM Rating400
Number of speeds3
Number of Fan Speeds3
LightingIncandescent
FiltersYes
ColorStainless Steel
Control TypePush Button
Width30 inches
Vent TypeDucted
Installation TypeUnder Cabinet

Summary

Electrical Requirements

Venting Requirements

Rear Discharge Venting

A 90° elbow may be installed immediately above the hood for rear discharge.

Vent System Length Calculation

Equivalent Vent Piece Lengths

Adds equivalent feet (meters) for each vent piece used in the system.

Location Requirements

Mobile Home Installation Standards

Specifies compliance with standards for manufactured home installation.

Product Dimensions

Cabinet Dimensions and Clearances

Installation Clearances and Chimney Notes

Details minimum distances to cooking surfaces and chimney extension options.

Related product manuals