EasyManua.ls Logo

Whirlpool Range User Manual

Whirlpool Range
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE HOMEOWNER.
HOMEOWNER: RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Wiring Diagrams are included in this package.
INSTALLATION
INSTRUCTIONS
FOR 30” EYELEVEL GAS RANGE
Before you begin, read the following instruc-
tions completely and carefully. If followed, they
will simplify the installation job.
IMPORTANT: OBSERVE ALL GOVERNING
CODES AND ORDINANCES.
INSTALLATION REQUIREMENTS
This lnstallatlon must conform with the American Natlonal Stand-
ard, Natlonal Fuel Gas Code ANSI 2223.1-l 980 * and local codes
and ordinances.
MOBILE HOME INSTALLATION AEGIJIREMENTS ARE
LISTED BELOW ON PAGE 4.
Input ratings shown on the rating plate [serial tag1 are for elevations
up to 2.000 feet. For elevations above 2,000 feet, ratings should be
reduced at a rate of 4% for each 1.000 feet above sea level.
PROPER GAS SUPPLY
1.
2.
3
4
5.
6.
This
range IS manufactured for use with NATURAL GAS.
It can be converted for use on LP GAS. The rating plate lo-
cated under the main top has the InformatIon on the type
of gas this unit can be used with. When in doubt check
with your local gas supplier.
Provide a gas supply line to the unit location. We suggest
using a
74”
rigid pipe, as smaller size pipe on long runs may
result in the gas supply not being sufflclent. Pipe joint
compounds resistant to the action of LP gas must be
used.
The supply line should be equipped with a shutoff valve.
This valve should always be located in the same room as
the range and should be in a locatlon that allows ease of
opening and closing. Do not block access to the shutoff
valve.
If local codes permit, it is recommended that flexible
metal tubing design-certified by the American Gas Asso-
ciation, be used for connecting the appliance to the gas
supply line. [The gas valve connectlon will accept a 3%”
male pipe thread.1
If rlgld pipe
IS
used as a gas supply line, a combination of
pipe fittings must be used to obtain an in-line connection
to the range.
The gas pressure regulator on this model
IS
convertible
and must be used. This regulator can be used on either
NATURAL or LP gases. The pressure regulator has fixed
outlet pressure at NATURAL and LP settings and these
cannot be changed. The fixed outlet pressure on NATU-
RAL gas setting is 4 inches W.C. On the LP gas setting
the outlet pressure
IS
10 inches W.C.
‘Copies of the standard llsted above may be obtained from:
AMERICAN GAS ASSOCIATION
1515 Wilson Boulevard
Arlington, Virginia 22209
1
Question and Answer IconNeed help?

Do you have a question about the Whirlpool Range and is the answer not in the manual?

Whirlpool Range Specifications

General IconGeneral
BrandWhirlpool
ModelRange
CategoryRanges
LanguageEnglish

Summary

Safety Information

If You Smell Gas

Critical steps to follow immediately if gas is detected: open windows, avoid switches, extinguish flames, call supplier.

Flammable Liquids Warning

Caution against storing or using flammable liquids like gasoline near the appliance.

Installation Requirements

Proper Gas Supply

Guidelines for connecting natural or LP gas, including pressure, pipe size, shutoff valve, and flexible tubing.

Inlet Pressure

Natural Gas Pressure

Specifies the minimum and maximum inlet pressure requirements for natural gas.

LP Gas Pressure

Specifies the minimum and maximum inlet pressure requirements for LP gas.

Electrical Requirements

Grounding Method

Details the requirement for a grounded 3-prong plug and receptacle for personal safety.

Line Pressure Testing

Testing Above 1/2 PSI

Procedure for testing gas supply piping at pressures exceeding 1/2 PSI.

Testing at 1/2 PSI or Lower

Procedure for testing gas supply piping at pressures equal to or less than 1/2 PSI.

Gas Conversion

Convert Natural to LP Gas

Steps to convert the range from natural gas to LP gas, including regulator and orifice adjustments.

Convert LP to Natural Gas

Steps to reconvert the range from LP gas back to natural gas, including regulator and orifice adjustments.

Space Requirements

Clearance Guidelines

Specifies zero clearance for top, back, and sides; 5-inch horizontal clearance for walls above cooktop.

Cabinet Depth

Recommends a maximum depth of 13 inches for overhead cabinets.

Cabinet Opening Diagram

Figure showing dimensions for cabinet opening and location of gas/electrical supply.

Shipping and Packing

Remove Shipping Skid

Instructions for removing shipping skid bolts and packing material.

Remove Packing Material

Instructions for removing tape and protective film from range parts.

Installation Procedure

Initial Steps

Steps to move the range, connect gas, plug in power, and check for leaks.

Leak Testing

Procedure for testing all supply line connections and the range itself for leaks using soapy water.

Gas Adjustments

Pilot Flame Adjustment

Adjusting top burner and oven pilot flames to the correct height (1/4-inch).

Burner Air Shutter Adjustment

Adjusting burner air shutters for the widest opening without flame lift.

Surface Burner Operation

Electric Ignition Models

Instructions for operating surface burners with electric ignition.

Flame Goes Out

Procedure for relighting burners if the flame extinguishes during cooking.

General Safety Warnings

Flame Size

Ensure top burner flame does not extend beyond the cooking utensil.

Storage Above Range

Warning about potential hazards of storing items in cabinets above the range.

Space Heating

Do not use range burners or oven for space heating purposes.

Oven Storage

Do not use the oven for storage space.

Wiring Diagram Location

Disconnecting Power Supply

Procedure

Steps to disconnect the power supply, including accessing the plug.

Mobile Home Installation

Requirements

Conformity with Federal Standard for Mobile Home Construction and Safety is required.

Installation Steps

Instructions for installing in a mobile home, including removing leveling legs and securing to floor.