CONTENTS
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . 2
SPECIFIC UNIT INFORMATION . . . . . . . . . . . . . . . . . . 3
DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
GAS PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
ELECTRICAL POWER CONNECTION . . . . . . . . . . . . 12
ELECTRICAL CONTROL CONNECTIONS . . . . . . . . . 13
COMBUSTION AIR AND VENT SYSTEM . . . . . . . . . . 14
CONDENSATE PIPING . . . . . . . . . . . . . . . . . . . . . . . . 24
SAFETY CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . 25
START-UP AND ADJUSTMENTS . . . . . . . . . . . . . . . . 26
FURNACE ACCESSORIES . . . . . . . . . . . . . . . . . . . . . 31
OPERATION AND MAINTENANCE . . . . . . . . . . . . . . . 33
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . 36
INSTALLATION
INSTRUCTION
CAUTION: READ ALL SAFETY GUIDES BEFORE YOU
START TO INSTALL YOUR FURNACE.
SAVE THIS MANUAL
HIGH EFFICIENCY
GAS-FIRED FURNACES
TUBULAR HEAT EXCHANGER SERIES
MODELS: P*UR / G9T-UP / FG9-UP (Upflow)
40 - 140 MBH INPUT
MODELS: P*DH / G9T-DH / FG9-DH (Downflow / Horizontal)
40 - 120 MBH INPUT
035-17477-001 Rev. A (801)
EFFICIENCY
RATING
CERTIFIED

Questions and Answers

  • C
    Clinton WalkerAug 15, 2025
    What to do if my York Furnace is showing 4 FLASH?
    • A
      Adam SmithAug 15, 2025
      If your York Furnace is showing 4 FLASH, it could be due to a dirty filter, improperly sized duct system, incorrect blower speed setting, incorrect firing rate, or a faulty blower motor. To resolve this, clean or replace the filter, check the duct size, adjust the blower speed, check the firing rate, or replace the blower motor as needed.
  • P
    pamelarobertsonAug 18, 2025
    What does 3 FLASH mean on my York Furnace and how to fix it?
    • A
      Austin UnderwoodAug 18, 2025
      If your York Furnace shows 3 FLASH, the possible causes are a faulty inducer, a blocked vent pipe, a broken pressure switch hose, or a faulty pressure switch. You should inspect and rectify each of these potential issues.
  • M
    Michael LiuAug 22, 2025
    Why is my York Furnace showing CONTINUOUS FLASH?
    • H
      Heather RyanAug 22, 2025
      A York Furnace showing a CONTINUOUS FLASH indicates a gas valve that leaks or is slow to close. Check the gas valve and control for proper operation.
  • S
    shaneclineAug 25, 2025
    What does 7 FLASH mean on my York Furnace?
    • G
      Gloria EllisonAug 26, 2025
      If your York Furnace displays 7 FLASH, this may be due to low gas pressure, a faulty gas valve, a faulty hot surface ignitor, or a burner problem. Inspect and repair any of the mentioned components.
  • S
    Samuel MercadoAug 28, 2025
    What does 5 FLASH mean on my York Furnace?
    • D
      Denise HansenAug 28, 2025
      If your York Furnace is showing 5 FLASH, it indicates a primary heat exchanger failure or burner problem. Check for proper combustion air and inducer operation, and manually reset the rollout switch after correcting any failures.
  • B
    Brenda EverettSep 1, 2025
    Why is my York Furnace showing 8 FLASH?
    • S
      Shelia FisherSep 1, 2025
      If your York Furnace is showing 8 FLASH, it could be due to low gas pressure or a faulty gas valve. Inspect the gas supply and valve.
  • O
    oclarkSep 4, 2025
    What does 2 FLASH mean on my York Furnace?
    • H
      henglishSep 4, 2025
      If your York Furnace is showing 2 FLASH, it indicates a faulty pressure switch or mis-wiring. Replace the faulty pressure switch.
  • J
    Julia YatesSep 7, 2025
    What does STEADY ON mean on a York Furnace?
    • M
      Mark JimenezSep 7, 2025
      If your York Furnace shows a STEADY ON, check the gas valve and control for proper operation.
  • E
    epatrickSep 12, 2025
    What does 11 FLASH mean on my York Furnace?
    • M
      Manuel DavisSep 12, 2025
      If your York Furnace displays 11 FLASH, it means an improper ground is present. Verify that the unit is properly grounded, and if the fault persists, replace the control.

Summary

General Information

Specific Unit Information

Gas Piping

Gas Supply and Installation Requirements

Covers gas supply line, pipe types, drop leg, union, and manual shutoff valve requirements.

Electrical Connections

Power Connection and Wiring

Details on field wiring, grounding, separate power supply, overcurrent protection, and disconnect switches.

Condensate Piping

Safety Controls

Overview of Safety Devices

Covers fuse, door switch, rollout switch, pressure switches, and limit controls for safe operation.

Start-Up and Adjustments

Ignition System Sequence

Details the sequence of events during burner ignition and operation.

Operation and Maintenance

Troubleshooting

Visual Checks and Fault Codes

Perform visual checks, review fault codes, and observe system response for troubleshooting.