DAB Submersible Pump Installation Instructions 2013 rev 1 12
PUMP SERVICE CHART con’t.
Fuses blow but overload doesn't trip
Fuse receptacle dirty or corroded
Loose connection in fuse box
Defective incoming power leads
Excessive motor starts per hour
Earth wire connected to wrong control box
terminal
Electric shock from water pipe
Defective (grounded) incoming power leads
Note: A motor down to earth or defective cable
will not cause a shock.
Earth wire connected to wrong control box
terminal
Pressure gauge oscillates, flow surges (snoring)
Water level too low in the well. (Flow through
pump greater than flow into well)
Electrolysis on motor and pump
Insufficient earth / earth leakage
NOTE: Always install borehole submersibles with ON/OFF switches and approved circuit breaker to protect
against motor damage and electrocution.