Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before
using this product. Keep this manual in a safe place for future reference.
Model # : ARC-122DS
INSTRUCTION MANUAL
WHYNTER ELITE 12,000 BTU DUAL HOSE DIGITAL PORTABLE
AIR CONDITIONER

Questions and Answers

  • K
    Katelyn BlackJul 27, 2025
    Why Whynter Elite ARC-122DS Air Conditioner won't turn on?
    • B
      Bruce BradshawJul 27, 2025
      Your Whynter Elite Air Conditioner might not be turning on due to several reasons: * There may be a power failure or outage – restore the power supply. * A switch, fuse, or breaker may have been tripped – flip the switch, change the fuse, or turn the breaker back on. Also, consider moving other appliances to a different circuit if too many are drawing power. * The power supply voltage could be too low – move the unit to a circuit with the correct voltage. * The power cord might be damaged – call for service; only authorized personnel should replace it. * The L.C.D.I. power plug may have tripped – press the Reset button on the plug. * The internal water reservoir might be full – drain the water. * There might be a loose internal connection – contact Whynter for service.
  • P
    phillipscatherineAug 15, 2025
    How to improve airflow and cooling in Whynter Elite ARC-122DS Air Conditioner?
    • C
      Carrie BaldwinAug 15, 2025
      If the air coming out of your Whynter Elite Air Conditioner isn't very cold or the airflow is weak: * Clean the air filters if they are dirty or obstructed. * Ensure that the air intake and exhaust are not blocked. Keep at least 20" of clearance from the air intake and minimize the length of the exhaust hose. * Make sure the unit is set to Cooling mode, not DEHUMIDIFY or FAN mode. * Increase the fan speed if it's set too low.
  • M
    Mr. Ethan WalshNov 5, 2025
    What to do if Whynter Elite ARC-122DS Air Conditioner compressor does not turn on?
    • D
      Debra FreemanNov 5, 2025
      If your Whynter Elite Air Conditioner turns on, but the compressor doesn't, consider these potential causes: * The room temperature might be outside the unit's operational range (64°F to 90°F). * Cooling mode may not be activated – press the Mode Control button until the Cooling indicator light appears. * The compressor might be experiencing a time delay – allow it 3 minutes to turn on after selecting Cooling mode. * The set temperature could be too high – lower the temperature, ideally to at least 5°F below the ambient temperature. * The internal water reservoir might be full, with a warning light displayed – drain the water manually or run the unit in fan-only mode to exhaust the water. Cooling will resume afterwards. * There may be a loose internal connection – contact Why...

Summary

Safety Precautions

Control Panel Overview

Button Functions

Details the operation of each button on the control panel.

Installation Guide

Filter Installation

Instructions for installing the washable pre-filter and activated carbon filter.

Water Drainage Procedures

Explains manual and continuous drainage methods for condensed water.

Location and Hose Installation

Proper placement of the unit and connecting exhaust/intake hoses.

Operation Instructions

Operating Modes

Explains Cooling, Dehumidifying, and Fan Only modes.

Remote Control Operation

Care and Maintenance

Troubleshooting Common Issues

Unit Not Turning On

Solutions for when the air conditioner fails to power on.

Unit Not Cooling

Diagnosing and fixing issues where the fan runs but the unit doesn't cool.