INSTRUCTION MANUAL · HUMIDIFIER
USE
Remove the top cover, ll water into the water tank, and put the top cover
back on. You can also take the water tank out and ll water directly into the
tank, and put the water tank back into the main base.
Check if the rated voltage meets the input voltage, and plug into the socket.
The display will light up and it beeps one time. 1 second later, the display will
turn off, and the “on/off” button will turn red, meaning the humidier is in
standby mode.
Touch the “on/off” button, the display will light up, and it will start to work in
AUTO mode. The display shows the auto symbol and current humidity. 10
seconds later, the display shows current temperature, and then change into
humidity. Current temperature and humidity showing will change once every
minute.
Humidier will decide running humidity based on current temperature as
below.
Constant humidity: touch the HUMIDITY button and you can select the
humidity from 30%RM to 75%. Touch the button once and it will increase
by 5%RH each time. When it reaches 75%, touch again and the display will
show “—” and the humidier will go back to AUTO mode. After setting the
preferred humidity, humidier will keep the memory and conrm by ashing
3 seconds. Once the display switches to show current humidity, it means that
the setting is nished, “%” will ash on the display.
When setting humidity is 1%RH~9%RH higher than current humidity, mist
output speed will run by the lowest (the rst) speed.
When setting humidity is 10%RH~15%RH higher than current humidity, mist
output speed will run by the middle (the third) speed.
When setting humidity is 15%RH higher than current humidity, mist output
speed will run by the highest (the fth) speed.
When current humidity is higher than setting humidity, humidier will turn
into sleep state. Once current humidity is 3%RH lower than setting humidity,
humidier will re-work in previous working mode till water shortage.
Mist output speed is adjustable under constant humidity function.
Temperature
of the air,
degrees
Celsius
≤19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 ≥37
Humidity (%)
65 60 58 57 55 53 50 48 45 43 40 38 36 35 34 32 31 30 25