LP SERIES
INSTALLATION INSTRUCTIONS
PN #49091081
Page 1 of 2
H.E. Williams, Inc. Carthage, Missouri www.hew.com 417-358-4065
Information contained herein is subject to change without notice.
REV.07/08/19JL
WARNING:
■
This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and
operation of the product and the hazards involved.
■
Make sure all electrical power is turned off while installing the fixture.
■
This luminaire must be adequately grounded for protection against
shock hazards and to assure proper operation.
■
Disconnect power before servicing.
■
LEDs are ESD (Electro Static Discharge) sensitive devices that can be
easily damaged if the proper ESD mitigating steps are not taken.
■
LEDs are very sensitive to mechanical damage. Caution must be taken
to avoid damage to the LEDs.
■
ESD or mechanical damage voids all warranties.
WIRING TROUBLESHOOTING
Step 1: Open the junction box. Step 2: Make wire connections in accordance with local
codes. Attach power supply and ground wires
using UL listed wire connectors. Driver accepts
#12 - #16 AWG stranded or solid wire. Please
consult factory for other driver configurations or
emergency driver wiring diagrams.
IF THE LEDS WILL NOT LIGHT:
■
Ensure the LEDs and wiring are
connected securely
■
Ensure the switch is turned on
BLINKING LEDS:
■
Ensure the incoming power is
stable
■
Ensure the dimmer switch is
compatible
LED Driver
BlackBlack
GROUND
White
Ground wire
if needed
White
0-10V + Purple
RECESSED FIXTURE INSTALLATION
Step 1: Bend mounting bracket leg into
vertical position.
Step 2: Bend mounting bracket base
into vertical position.
Step 3: Install the fixture into the
grid ceiling.
Mounting bracket le
Mounting
bracket base
1x4 2x2 2x4
23-3/4
23-3/4