Troubleshooting
Cause
Solution
Damaged electric cables
Check electrical cable, replace it
if necessary.
Interior cable connections
damaged
Open rear cover, check interior
cable connections, repair them.
On/off switch does not function
Check on/off switch, replace it if
necessary.
Outlet completely clogged or
closed
Unblock or open outlet.
Wrong direction of cylinder valve
after first assembly/disassembly
made by the user
Reinstall cylinder valve and place
it in the right direction.
Bearings are loose or damaged
Replace bearings.
Screws in connecting rod loose
Tighten or replace screws.
Air connection not tight.
Seal air connection with
insulating tape.
Air hose torn off
Re-mount the air hose.
Screws of cylinder cover loose.
Tighten screws.
Valve screws and diaphragm
screws loose or in wrong posi-
tion.
Open front cover, tighten screws,
and place the diaphragm screws
in right position.
Valve destroyed because of too
long a work with too high a pres-
sure.
Replace valves or cylinder cover.