MAINTENANCE AND SERVICE 13
SERVICE SCHEDULE
IMPORTANT; The Honda HP500H Power Carrier will require
additional daily checks, services and adjustments in addition to
those listed below, refer to the appropriate section of the HP500H
Operators Handbook for details.
Daily or every 10 operating hours check, or carry out the following:-
Hydraulic oil level & the condition of hoses
Oil leaks, loose items and fixings
All levers, controls and cables for correct operation, (binding)
Lubricate (oil) control lever pivots and linkages as necessary
Grease the skip pivot and scissor pins
Lubricate (oil) the skip & scissor ram pivots & scissor pivot pins
First 100 hours of operation:-
Change the hydraulic oil, clean the hydraulic oil filter strainer.
Every 500 hours of operation (more frequently in dusty/dirty
conditions)
Change the hydraulic oil, clean the hydraulic oil filter/strainer.
Clean the hydraulic oil filler strainer/breather assembly.
Note:- the oil level should only be checked when the engine is
switched off, the skip is at rest on the stops, the scissors lowered to
the rest position and any residual hydraulic pressure remaining in
the system has been ‘dumped’ as described under ‘Safe Working’.
Wear suitable gloves to protect the skin.
On the rear vertical face of the hydraulic tank there is a small sight
glass, the hydraulic oil level is correct when the oil is visible in the
centre of the glass. If the oil level is to low, clean the area around the
filler/breather on top of the hydraulic tank. Remove the cap and
carefully top up the level until it reaches the centre of the glass.
Refer to the Technical Information section of this manual for the
correct grade of hydraulic oil.