SECTION 7 –
PLUMBING
7-4
Always fill the fresh water tank at an approved
potable water filling facility or a known purified
drinking water source.
The tank is filled through the City Water
Connection (Fresh Water Inlet) located inside the
water service center.
The Fresh Water valve routes the water from
the city water hose to the fresh water tank for
filling.
1. Attach hose to the Fresh Water Inlet.
2. Turn the Fresh Water valve to Tank Fill
position.
3. Turn city water supply ON.
4. Use the level display on the monitor panel to
oversee filling of the tank, or when the tank is
full, water will flow from tank vent tube
beneath coach.
5. Turn OFF city water supply and disconnect
from the Fresh Water Inlet.
6. Turn Fresh Water valve to Normal position to
use the water pump. The Tank Fill position is
only for pressure filling the water tank from
the city water hose connection.
Using City Water
When connected to an outside source of water,
the water bypasses the water pump and storage
tank and supplies pressure directly to individual
faucets and toilet. A check valve built into the
pump prevents water from entering the pump and
filling the storage tank.
1. Connect hose to Fresh Water Inlet as
described in previous steps.
Fresh (City) Water Connection
“Fresh Water Inlet”
(Located in the water service center)
-Typical View
Fresh Water Valve
(Located in water service center)
-Typical View
NOTICE
Do not leave fresh water connection
unattended when filling tank. Failure to
comply may result in tank expansion and
property damage.
Fresh Water Valve
(Located in water service center)