17. DISMOUNTING THE ACCUMULATOR
Loosen the screws carefully with a 4 mm hex key.
Note: There are two screws in each hole.
Use a 3 mm hex key.
18. CONTROLLING THE ACCUMULATOR
Put a long rod down the hole the accumulator to check if the accumulator is
pressurized.
If the diaphragm can be pushed a lot, the accumulator must be charged with
Nitrogen or the diaphragm is defective.
In case of a defective diaphragm, the accumulator must be replaced
Loosen the charging screw with a 6 mm hex key.
If the accumulator is in order, you can hear a whistling sound of Nitrogen. In this
case merely recharge the accumulator.
If there is no whistling sound, the diaphragm is probably damaged and must be
replaced.