ELECTRICAL
Electricwiringonyourunit isnotrequiredas the unit
hasbeenpro-wiredatthe factory. Besuretoconnect
theunitto agrounded110-120voltA.C.,60 Hz(cycle)
electricalsupply.
MAINTENANCE
CLEANING...
Thecabinetsurfaceofthisunitis highlyresistantto
scaleandcorrosion.A softcloth,warm water and a
mildcleanserwillbringallsurfacesbackto like-new
appearance.Donotuseharshcleansers,steelwool
orsandpaperinnormalcleaningof cabinet,
OILING...
Thefan motorwas permanentlylubricated atthe fac-
toryendrequiresnooiling.
FILTER/PADREPLACEMENT...
Formaximumcooling/humidifyingefficiency,thefilter
shouldbechangedtwice a year,ormorefrequently
dependingonlocalair andwater conditions.For
instance,inareaswherethe mineralcontentofthe
waterishigh,depositsmaybuildupinthefilter
restrictingtheairflow. Replacementfilters areavail-
ablethroughyourlocaldealerorAdoheAir,Inc.
TOREPLACEFILTER/PAD.,.
Removethescrewfromeachsideofbackpaneland
removethepanel.Removethecrossbar(padretainer).
Removethefilter/pad bybendingtabsholdingit tothe
frame endremoveanddiscardthepad.Reversethe
processtoinstallnewfilter/pad media.Make surethe
filter padiswrappedaroundthedistributortubethe
samedirectionasyouroldfilter pad.