Details on the operational capabilities and applications of the iAStar AS380.
Description of the main converter unit and its role in the system.
Procedure for setting parameters using the Para.Select submenu.
System status and diagnostic information.
Core operational parameters for the system.
Parameters for adjusting the S-curve of elevator movement.
Parameters for PID control adjustment of elevator movement.
Configuration for firefighting switch and mode selection.
Parameter for standard or Hongkong brake monitoring.
Configuration for emergency levelling orientation.
Fine tuning for stop UP during direct run or creep run.
Fine tuning for stop DOWN during direct run or creep run.
Delay between inverter STOP and brake contactor OFF.
Setting for inspection mode end switch and traction.
Settings for button beep and flashing for call buttons.
Defines door mode based on priority (hold close, make close).
Classifies hall calls based on type (simple, selective, disabled).
Defines door operation mode (selective control or both doors).
Enables relevelling with open or pre-open doors, requires security circuit.
Parameter to block specific floors using a bitmask.
Parameter to monitor the door lock status (OFF/ON).
Enables security circuit detection with add relay or high voltage inputs.
Blocks floors based on time or key-switch settings.
Selects door open functionality during inspection or normal operation.
Sets speed at self-learning mode for analogue control.
Configuration of inverter modes (V/F, Vector without/with encoder).
Parameter for selecting motor type (Asynchronous/Synchronous).
Specifies the type of encoder used (Incremental, SinCos, EnDat).
Sets the direction of motor rotation (positive/negative).
Sets the encoder phase angle for tuning.
Selects the function of parameters F246-F255 based on other settings.
Prerequisites and checks before starting the commissioning process.
Configuration parameters for elevator group operation.
Guidelines for checking and adapting parameters during commissioning.
Details on parameters related to the speed controller.
Description and handling of the HDR Lock Error.
Description and function of the re-levelling sensor.
Overview of iMS45 sensors for simplified installation and adjustment.
Explanation of signal inputs and their LED indications on the AS.T030 board.
Overview of the AS380 main board and its components.
Detailed terminal connections for the AS.T029 main board.
Description of the SM02/H cartop box module.
Description of the SM09IO/B Add-ON module.
Description of the SM02/G car panel board module.
Details on the SM03 button module and its floor connections.
Description of the SM04HRF floor module.
Description of the safety circuit and its three sections.
Information on optional security switches and their connection.
Guidelines and warnings regarding by-passing security circuits.
General guidelines and checks for acceptance testing.
Procedure for performing isolation measurements on the lift controller.
Procedure to check the run-time monitoring function.
Procedure to check the movement of end switches.
Test for the effectiveness of the one-sided brake system.
Procedures for monitoring contactor and brake switch functionality.
Information, principle, and functional check of the DKU monitoring system.
Procedures for checking DKU effectiveness, reset, and inspection control.
General instructions, security, and functional principles for A3 protection checks.
Procedures for checking UCM function with trundle and inverter.
Example calculation for determining the braking distance.