EasyManua.ls Logo

WITTUR iAStar AS380 - User Manual

WITTUR iAStar AS380
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Manual
iAStar AS380
frequency converter with integrated lift control
system
Version E2.0 (MAI)

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the WITTUR iAStar AS380 and is the answer not in the manual?

Summary

iAStar AS380 System Overview

Scope of Operation

Details on the operational capabilities and applications of the iAStar AS380.

System Components Overview

Integrated Frequency Converter iAStar AS380

Description of the main converter unit and its role in the system.

Hand Device Operation

Parameter Setting via Para.Select

Procedure for setting parameters using the Para.Select submenu.

Menu Tree and Parameters

Monitor Functions

System status and diagnostic information.

Basic Parameters

Core operational parameters for the system.

Comfort Adjust: S-curve

Parameters for adjusting the S-curve of elevator movement.

Comfort Adjust: PI Adjust

Parameters for PID control adjustment of elevator movement.

Firefighting Switch Configuration

Configuration for firefighting switch and mode selection.

Brake Switch Monitoring

Parameter for standard or Hongkong brake monitoring.

EVA Mode Configuration

Configuration for emergency levelling orientation.

UP Levelling Adjustment

Fine tuning for stop UP during direct run or creep run.

Down Levelling Adjustment

Fine tuning for stop DOWN during direct run or creep run.

Zero Speed Brake Delay

Delay between inverter STOP and brake contactor OFF.

Inspection ES Mode Settings

Setting for inspection mode end switch and traction.

Door Quitting Mode Settings

Settings for button beep and flashing for call buttons.

Priority Mode Settings

Defines door mode based on priority (hold close, make close).

Hall Call Classification

Classifies hall calls based on type (simple, selective, disabled).

Door Operate Mode

Defines door operation mode (selective control or both doors).

Relevelling Enable Settings

Enables relevelling with open or pre-open doors, requires security circuit.

Block Floor Number Setting

Parameter to block specific floors using a bitmask.

Door Lock Monitoring

Parameter to monitor the door lock status (OFF/ON).

Security Circuit Detection

Enables security circuit detection with add relay or high voltage inputs.

Block Floor During Time

Blocks floors based on time or key-switch settings.

Door Open Selection

Selects door open functionality during inspection or normal operation.

Self-Learning Analogue Speed

Sets speed at self-learning mode for analogue control.

Inverter Mode Configuration

Configuration of inverter modes (V/F, Vector without/with encoder).

Motor Type Selection

Parameter for selecting motor type (Asynchronous/Synchronous).

Encoder Type Specification

Specifies the type of encoder used (Incremental, SinCos, EnDat).

Direction of Rotation Setting

Sets the direction of motor rotation (positive/negative).

Offset Phase Angle Setting

Sets the encoder phase angle for tuning.

Parameter Function Selection

Selects the function of parameters F246-F255 based on other settings.

Error Code Reference

Commissioning and Installation Run

Condition for Commissioning Run

Prerequisites and checks before starting the commissioning process.

Group Function Configuration

Configuration parameters for elevator group operation.

Parameter Check and Adaptation

Guidelines for checking and adapting parameters during commissioning.

Parameter Speed Controller

Details on parameters related to the speed controller.

HDR Lock Error Description

Description and handling of the HDR Lock Error.

Shaft Copying System

Re-levelling Sensor

Description and function of the re-levelling sensor.

Intelligent Magnetic Sensors iMS45

Overview of iMS45 sensors for simplified installation and adjustment.

Correct Signal Inputs at AS.T030 (LEDs)

Explanation of signal inputs and their LED indications on the AS.T030 board.

AS380 Main Board and Modules

AS380 Main Board AS.T029

Overview of the AS380 main board and its components.

AS.T029 Terminal Connections

Detailed terminal connections for the AS.T029 main board.

SM02;H Cartop Box Module

Description of the SM02/H cartop box module.

SM09 IO;B Add-ON Module

Description of the SM09IO/B Add-ON module.

SM02;G Car Panel Board Module

Description of the SM02/G car panel board module.

SM03 Button Module

Details on the SM03 button module and its floor connections.

SM04 HRF Floor Module

Description of the SM04HRF floor module.

Security Section and Testing

Security Circuit Overview

Description of the safety circuit and its three sections.

Optional Security Switches

Information on optional security switches and their connection.

By-passing Security Circuits

Guidelines and warnings regarding by-passing security circuits.

Advice of Acceptance Test

General guidelines and checks for acceptance testing.

Isolation Measurement Procedure

Procedure for performing isolation measurements on the lift controller.

Run-Time Monitoring Check

Procedure to check the run-time monitoring function.

End Switch Movement Test

Procedure to check the movement of end switches.

Brake Effectiveness Test

Test for the effectiveness of the one-sided brake system.

Contactor and Brake Switch Monitoring

Procedures for monitoring contactor and brake switch functionality.

Triangle Monitoring (DKU)

Information, principle, and functional check of the DKU monitoring system.

DKU Effectiveness and Inspection Control Checks

Procedures for checking DKU effectiveness, reset, and inspection control.

A3 Check Instructions

General instructions, security, and functional principles for A3 protection checks.

UCM Functional Checks

Procedures for checking UCM function with trundle and inverter.

Braking Distance Calculation Example

Example calculation for determining the braking distance.

WITTUR iAStar AS380 Specifications

General IconGeneral
BrandWITTUR
ModeliAStar AS380
CategoryMedia Converter
LanguageEnglish