EasyManua.ls Logo

Wizmart Technology NB-920N SERIES User Manual

Default Icon
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Guarantee
T
he gas detector has been tested to comply with the applicable
regulations and
it has been manufactured with great care.
The guarantee runs for 5years from purchase of the equipment by the end consumer.
The guarantee can only be upheld if the unmodified equipment is returned together with
the dated receipt, after it has been packed and adequately stamped. Please it clued a
brief, written description of the defect with the equipment being complained about.
If the guarantee claim is authorized, then the manufacturer will choose either repair the
equipment within reasonable period or to exchange it. If the guarantee claim is unjustified
(e.g., made after expiry of the guarantee period, or the defect is not covered by the
guarantee claim), then the manufacture will try to repair the
equipment economically.
The guarantee liability does not refer to natural wear and tear, alteration by environmental
influences or damage cause by transportation; nor to damage which has occurred as a
result of noncompliance with the mounting instructions or improper installation.
The supplied batteries are excluded from the guarantee.The manufacturer is not liable for
indirect or consequential damage, nor for damage to property.
WIZMART TECHNOLOGY INC.
2F, Building B, #143, Qi-Xin Road, Jiang Dong Hi-Tech part,
Ning Bo City 315040, Zhe-Jiang,China
TEL: +86-1395-780-7788 FAX:+86-1395-780-2288
Functions
Red LED:(alarm)
It flashes and a supplementary
acoustic Signal generator (transducer)
sounds intermittently in the event of an
alarm=see conduct in the
event of an alarm.
Orange LED:
illuminates in the event of
an sensor interruption.
Green LED:(flashing)
The equipment is ready for
operation approximately
4 minutes after connecting it
to the electrical power supply.
Permanent light: the equipment
is ready for operation:" Power on
Test and muting switch:
Electrical power
Test knob
Operate once a month to
Connection:
test the function. The red and orange AC 230v~50Hz in the socket
LEDs will flash and acoustic signal to outlet. No function when
new will sound intermittently. he electrical power supply
is interrupted.
Muting switch:
You can switch off
the acoustic alarm tone in the event
Or,12V direct current
of an alarm. (DC) From a battery or rectifier
The red LED will continue to flash or example. No function
and short signal tone will sound when the electrical power
approximately event 16 specs. supply is interrupted, or when
WIZMART GAS DETECTOR
NB-920 SERIES
wizmart
USER MANUAL
Gas Detector
Japanese
Semiconductor
sensor technology
5-Year Guarantee
230
Version
110V
Version
12V
Version
NB-920N SERIES: Natural gas detector
NB-920L SERIES: Propane gas detector
NB-920N/L-R: Natural gas/Propane gas detector with relay out
NB-920N/L-I:Natural gas/Propane gas detector with
interconnection
Great danger: An easily ignitable mixture of gas exists when
the above named gases escape and mix with oxygen .Even
the smallest spark can lead to an explosion.
Application: house, flat, caravan or mobile home, yacht or
motors boat, WIZMART Gas Detector alarms you well before
the explosive level is reached.
Mounting locations: LPG NB-920L
2a
2b
Propane is heavier than air and it therefore
fall to the bottom. Fasten the gas detector
approximately 30 cm above the floor.
Propane Gas installation point
(NB-920L series)
Question and Answer IconNeed help?

Do you have a question about the Wizmart Technology NB-920N SERIES and is the answer not in the manual?

Wizmart Technology NB-920N SERIES Specifications

General IconGeneral
ModelNB-920N SERIES
Detection MethodPassive Infrared (PIR)
Output TypeWireless Signal
Power SupplyBattery
Operating Temperature-10°C to 50°C
Communication Distance100m (open area)
Tamper ProtectionYes
InstallationWall Mount
Detection Range12m
Operating Voltage3V

Summary

Guarantee Information

Device Functions and Indicators

Red LED (Alarm)

Flashes and sounds intermittently during an alarm event.

Orange LED

Illuminates when the sensor is interrupted.

Green LED (Flashing)

Indicates the equipment is ready for operation after approximately 4 minutes.

Test and Muting Switch

Allows testing of functions and muting of acoustic alarms.

Gas Detector Mounting Locations

LPG NB-920L Mounting Locations

Specifies mounting positions for LPG detectors, considering propane's density.

Natural Gas NB-920N Mounting Locations

Details mounting for natural gas detectors, considering methane's density.

Alarm and Safety Procedures

Possible False Alarms

Explains factors that can cause the system to trigger a false alarm.

Conduct in Event of an Alarm

Provides critical steps to take when the gas detector alarms.

Technical Specifications

Advanced Mounting Configurations

Mounting for Relay Function

Details wiring and options for integrating with external relay devices.

Mounting for Interconnection

Explains how to connect multiple detectors together for system-wide alarms.