Electronics and Gas Theory
Integrated Modules
Integrated Modules
2-7
#826498 - Revision B - December, 2016
Wake-Up Mode - All Models
Entering Wake-Up Mode
Touch ON/OFF pad on any inactive control zone.1.
All LEDs for that control zone flash until a power level is set.•
A valid key press must be made within 10 seconds or control zone returns to Idle Mode.•
Valid key presses in Wake-Up Mode
SIM, LO or MLT – Activates the control zone at power level 1.1.
HI – Activates the control zone at power level 10.2.
BOOST - CI152TF/S - Activates the control zone at power level Boost.3.
“…” – Activates the control zone at a power level 2 through 9. 4.
ON/OFF – Touch any other control zone ON/OFF pad causes that control zone to enter Wake-Up Mode.5.
ON/OFF – Retouch of same ON/OFF pad causes control zone to return to Idle Mode.6.
ALL OFF – Causes all active control zones to return to Idle Mode.7.
CI152TF/S: Notes and Restrictions in Wake-Up Mode
If a valid key press is made but no pan is sensed on the coil assembly in 30 seconds the control zone•
returns to Idle Mode.
During the 30 second wait, the “...” LEDs for that control zone flash the power level selected.•
If a bridge is activated and a pan is detected on one control zone but not all control zones being bridged the•
“...” LEDs for the unsensed control zones flash the power level that has been selected.
If after 2 minutes one or more of the control zones in the bridge still does not sense a pot, all control zones•
in the bridge return to Idle Mode, including the sensed control zone.
Display states in Wake-Up Mode
All displays for a given control zone are flashing on/off.•
ALL OFF display is turned on.•
All other displays are off. •
Operational Mode
When any control zone is active at any power level greater than 0.
Entering Operational Mode from Wake-Up Mode - All Models
SIM/MLT/LO – Activates the control zone at power level 1.1.
HI – Activates the control zone at power level 10.2.
BOOST - CI152TF/S - Activates the control zone at power level Boost.3.
“…” – Activates the control zone at power level 2 through 9. Corresponding to the “.” which was pressed. 4.
Exiting Operational Mode
ON/OFF – Touch the same ON/OFF pad returns control zone to Idle Mode.•
ALL OFF – All active control zones return to Idle Mode.•