Integrated Modules
Integrated Modules
Electronics and Gas Theory
2-6
#826498 - Revision B - December, 2016
Lock Mode - All Models
No pad can function except for the LOCK pad or the pads associated with entering Diagnostic Mode.
Entering Lock Mode
Enter lock mode by holding LOCK pad for 3 seconds when in Idle Mode.1.
Engages after ten continuous minutes of Idle Mode. •
After power up sequence.•
Annunciator sounds Acceptance beep when Lock Mode is entered.•
LOCK LED is visible.•
Annunciator sounds Failure beep if any control zone is active when trying to enter Lock Mode. •
Exiting Lock Mode
Touch and hold the LOCK pad for 3 seconds.1.
CE152TF/S and CI152TF/S - if LOCK pad is held for more than 10 seconds unit relocks.•
SM15TF/S, FM15TF/S, GM15TF/S, and TM15TF/S - if LOCK pad is held for more than 7 seconds unit•
relocks.
Annunciator sounds Acceptance beep to indicate Lock Mode has been exited.•
LOCK LED turns off and control zones enter Idle Mode.•
Valid key presses in Lock Mode
LOCK pad for exiting Lock Mode.•
CE152TF/S, CI152TF/S, and TM15TF/S - touch and hold “+” and “-” pads for 5 seconds to enter•
Diagnostic Mode.
SM15TF/S, FM15TF/S, and GM15TF/S - touch and hold “ALL OFF” pad for 5 seconds to enter Diagnostic•
Mode.
Display states in Lock Mode
LOCK display is on. •
All other displays are off.•
Idle Mode - All Models
Unit is unlocked and control zones are inactive.
Valid key presses in Idle Mode
LOCK – Touch and hold LOCK pad to enter Lock Mode.•
ON/OFF – Touch any control zone ON/OFF pad places that control zone in Wake-Up Mode. •
TIMER – Touch TIMER pad activates the Timer.•
DRAIN - SM15TF/S - liquid temperature below 140° F, a touch and hold of the DRAIN pad for three seconds•
results in an audible chime and the drain valve will open for two minutes.
Display states in Idle Mode
All displays are off.