Electronics and Gas Theory
Integrated Modules
Integrated Modules
2-5
#826498 - Revision B - December, 2016
Fan - CI152TF/S
Fan control is determined by the temperature on the heat sink.
A very high power request, such as two elements on 100% or one on boost switches the fans on independ-
ently of the heatsink temperature.
After generator is off, fan continues to run until heat sink temperature is below 113° F, or up to 600 seconds.
Fan is limited to low speed when the generator is off.
Temperature thresholds:
113° F - start low speed
131° F - start high speed
Fan - TM15TF/S
Fan control is determined by the temperature on the heat sink.
A very high power request, such as both elements on 100% switches the fan on independently of the
heatsink temperature.
After generator is off, fan continues to run until heat sink temperature is below 113° F, or up to 600 seconds.
Fan is limited to low speed when the generator is off.
Temperature thresholds:
113° F - start low speed
131° F - start high speed
Modes
Power Up Mode - All Models
All LED indicators are on for two seconds.
Timer digits will indicate the appliance type ‘SS’ for SM15TF/S, ‘FF’ for FM15TF/S, and ‘LL’ for GM15TF/S. The
control will default to SM15TF/S if the appliance type cannot be determined due to an EEPROM issue or if the
EEPROM is not programed.
After LED power up sequence the annunciator sounds the Acceptance beep.
During the Acceptance beep the unit enters Lock Mode.
LOCK display is on.