Integrated Modules
Integrated Modules
Electronics and Gas Theory
2-4
#826498 - Revision B - December, 2016
Timer
General Information - All Models
Available in any mode except Lock Mode, Sabbath mode, User Option mode, and Diagnostic mode.•
The 2-digit display is blank unless there is a fault, in Diagnostic mode, or in Showroom mode.•
Shows minutes until the timer reaches 1 minute. •
Switches to seconds at 1 minute, and counts down from 60 seconds.•
Timer is paused until 3 seconds after the last change in value then countdown begins.•
Adjusting the time on a running timer resets the seconds to zero. •
If counting down seconds and the “-” pad is touched the timer stops without alarm.•
Maximum time allowed is 99 minutes. •
Minimum time allowed is 1 minute. •
Timer turns off after 10 seconds if no time is entered. •
Starting the Timer - All Models
1. Unlock the unit.
2. Press and release the TIMER pad.
3. Time increases and decreases with a touch of the “+” or “-” pad.
If the “+” or “-” pad is held continuously for 3 intervals the count rate increases.•
If the “+” or “-” pad is held continuously for additional 3 intervals, the count rate increases again.•
A continuously held “+” or “-” increases in this manner: 00, 01, 02, 03, 04, 05, 10, 15, 20, 30, 40, 50,•
60, 70, 80, 90, 99.
Ending the Timer - All Models
Touch of the TIMER or “-” pad stops Timer Complete beep and clears the display.1.
At 60 seconds the One Minute Remaining beep sounds. •
At 00 the Timer Complete beep sounds until acknowledged.•
Touch of the “+” pad adds time to the timer as described above.2.
Display States of the Timer - All Models
When active the 2-digit display and Timer are on. •
Other displays are as described in Idle Mode or Operational Mode.•
Fan
Fan - CE152TF/S
Fan control is determined by the temperature on the heat sink. •
After element assemblies are off fan continues to run until heat sink temperature is below 113° F, or up to•
600 seconds.
Fan is limited to low speed when the element assemblies are off.•
Temperature thresholds:
• 113° F – start low speed
• 131° F – start high speed