Integrated Modules
Integrated Modules
Electronics and Gas Theory
2-4
#826498 - Revision B - December, 2016
Timer
General Information - All Models
Available in any mode except Lock Mode, Sabbath mode, User Option mode, and Diagnostic mode.
The 2-digit display is blank unless there is a fault, in Diagnostic mode, or in Showroom mode.
Shows minutes until the timer reaches 1 minute.
Switches to seconds at 1 minute, and counts down from 60 seconds.
Timer is paused until 3 seconds after the last change in value then countdown begins.
Adjusting the time on a running timer resets the seconds to zero.
If counting down seconds and the “-” pad is touched the timer stops without alarm.
Maximum time allowed is 99 minutes.
Minimum time allowed is 1 minute.
Timer turns off after 10 seconds if no time is entered.
Starting the Timer - All Models
1. Unlock the unit.
2. Press and release the TIMER pad.
3. Time increases and decreases with a touch of the “+” or “-” pad.
If the “+” or “-” pad is held continuously for 3 intervals the count rate increases.
If the “+” or “-” pad is held continuously for additional 3 intervals, the count rate increases again.
A continuously held “+” or “-” increases in this manner: 00, 01, 02, 03, 04, 05, 10, 15, 20, 30, 40, 50,
60, 70, 80, 90, 99.
Ending the Timer - All Models
Touch of the TIMER or “-” pad stops Timer Complete beep and clears the display.1.
At 60 seconds the One Minute Remaining beep sounds.
At 00 the Timer Complete beep sounds until acknowledged.
Touch of the “+” pad adds time to the timer as described above.2.
Display States of the Timer - All Models
When active the 2-digit display and Timer are on.
Other displays are as described in Idle Mode or Operational Mode.
Fan
Fan - CE152TF/S
Fan control is determined by the temperature on the heat sink.
After element assemblies are off fan continues to run until heat sink temperature is below 113° F, or up to
600 seconds.
Fan is limited to low speed when the element assemblies are off.
Temperature thresholds:
113° F – start low speed
131° F – start high speed