Troubleshooting
Integrated Modules
Integrated Modules
4-5
#826498 - Revision B - December, 2016
Heat Sink Performance notes - CI152TF/S
Touch the front control zone SIM/MLT or HI pad cycles through the heat sink temperatures.1
Front control zone SIM/MLT and HI LEDS are on.•
Front control zone displays dimmed 1, 2, or 3 “.” to indicate heat sink number, with one “.” on to•
indicate which heat sink temperature is displayed.
First LED is generator board #1.•
d. RTD Temperature Test - SM15TF/S, FM15TF/S, and GM15TF/S
GM15TF/S - No RTD - 2 digit display shows “--” and temperature display is blank.•
Touch “+” pad during the Control Temperature Readout.1
Four “.” are displayed on the rear control zone.•
Touch of front control HI will toggle to the next RTD in sequence.•
Touch of front control LO will toggle to the previous RTD in sequence.•
The timer display will show “LI” when the Main RTD temperature is displayed.•
The timer display will show “PA” when the RTD Steamer Fill Sensor temperature is displayed.•
“-” pad returns to Control Temperature Readout and “+” pad advances to error code indicator.2
e. Coil Temperature Test - CI152TF/S and TM15TF/S
CE152TF/S - This mode is present but shows 00 as it is not active.•
Touch “+” pad during the Heat Sink Temperature test. 1
Five “.” are displayed on rear control zone.•
2-digit display shows the coil temperature in °C. •
Over 99° C (210° F), the decimal point of the 2 digit display turns on to indicate the temperature is•
100° C (210° F) or higher.
CI152TF/S front SIM/MLT and HI are on. Touch the front control zone SIM/MLT or HI pad cycles2
through the coil temperatures.
Front control zone displays dimmed 1, or 2 “.” to indicate coil number, with one “.” on to indicate•
which coil temperature is displayed.
• First LED is coil assembly and NTC #1
• Second LED is coil assembly and NTC #2
TM15TF/S rear LO and HI pad cycles through the coil temperatures3
Front control zone displays one or two “.” to indicate which coil temperature is being displayed.•
First LED is coil #1•
Second LED is coil #2•
“-” pad returns to Heat Sink Temperature Test and “+” pad advances to Error Code Indicator.•
Coil Temperature Performance Impact - CI152TF/S
160° C (320° F) boost is disabled for affected zones.•
240° C (464° F) affected zones are limited to 60% power. •
260° C (500° F) affected zones are turned off.•
285° C (545° F) all zones are turned off.•