14
LED Display Reason Operation
Display in "red"
Jumper cables
connected with reversed
polarity to the car
Connect the batte clamps
to the correct positive and
negative terminals
Display in
"yellow"
Correctly connected
car batte, but batte
voltage is below 9V, and
the core temperature is
above 0℃/32℉
BOOST button for 2 seconds to
use the forced boot function
"OUT&IN"
ashing
High-temperature
protection activated,
displaying core
temperature
overheating
When the core temperature
reaches 55°C/131℉,
the product activates
temperature protection. Once
the temperature drops to
45°C/113℉, it can resume output
"IN" ashing
Low-temperature
protection activated,
displaying core
temperature too low
When the core temperature
drops below -20°C/-4℉, the
product activates temperature
protection. It can resume output
when the temperature rises to
0°C-3°C/32℉-37.4℉
"Sta"ashing
Buzzer sounding,
silence after 30 seconds
Overcurrent detected, stop
staing vehicle, disappear for
30S
Within 10 minutes, if the
vehicle is staed more
than 4 times, the buzzer
will sound, and after 30
seconds, the buzzer will
be silenced. The 'START'
will continue to ash
Stop staing the vehicle,the
safety mode will disappear after
10 minutes