Beermaster Plus Cooling Range
Installation and
maintenance instructions
Question and Answer IconNeed help?

Do you have a question about the WOLSELEY Beermaster Plus BMIEP-448-48 and is the answer not in the manual?

WOLSELEY Beermaster Plus BMIEP-448-48 Specifications

General IconGeneral
BrandWOLSELEY
ModelBeermaster Plus BMIEP-448-48
CategoryAir Conditioner
LanguageEnglish

Summary

1. Introduction

Glossary of terms

Provides definitions for abbreviations and terms used in the manual.

Health and safety

Highlights essential safety information and precautions for handling and installing the equipment.

Before installation

Outlines crucial checks and conditions to ensure before commencing the installation process.

2. Planning the installation

Positioning the condensing unit

Details guidelines for optimal placement of the condensing unit for performance and access.

How to gain access to the condensing units

Provides step-by-step instructions and illustrations for accessing the internal components of the condensing unit.

Positioning the evaporator

Gives instructions for locating and positioning the evaporator unit, including clearance requirements.

3. Installing the units

Mounting the condensing unit on a wall bracket

Guides on securely mounting the condensing unit using wall brackets, detailing spacing and fixings.

Mounting the evaporator unit on a wall bracket

Provides instructions for wall-mounting the evaporator unit, including bracket spacing and fixing methods.

4. Pipe sizing

Using interconnecting pipe sizing charts

Explains how to use tables to select appropriate pipe sizes based on equivalent run length and cellar temperature.

5. Pipework installation - supports and routing

6. Brazing

7. Expansion valve phial location

8. Drainage

9. Electrical supply & function

Cable sizing

Provides guidance on selecting appropriate cable sizes according to IET regulations for electrical connections.

Cable connection / termination

Details how to properly connect and terminate electrical cables for both single-phase and three-phase units.

10. Power entry to the condensing units

11. Power entry to the evaporators

12. Pressure testing

13. Evacuation

14. Refrigerant charging

15. Approximate refrigeration charge

16. Commissioning

Final checks

Lists essential checks to perform before operating the units after installation and charging.

Compressor rotation

Explains how to verify and correct the compressor's rotational direction for three-phase units.

17. BMOP functions

Fan speed controller BMOP

Describes the operation and adjustment of the BMOP fan speed controller based on condensing pressure.

HP/LP switches

Low pressure setting

Explains the low-pressure cut-out and cut-in settings for compressor protection.

High pressure setting

Describes the high-pressure trip setting and automatic reset for compressor protection.

Isolation

BMOP fan

Describes the EC fan set for the BMOP unit and its control via the fan speed controller.

18. BMIEP functions

Electronic controller

Details the BMIEP controller's setpoint range, LEDs, and anti-cycle timer for compressor protection.

Controller set-point adjustment

Guides on how to adjust the temperature set point using the controller's buttons.

Controller operation

Explains the different modes of operation for the controller and its display.

Defrost

Outlines the conditions and procedures for enabling and managing the defrost function, including sensor requirements.

Controller alarm output & fault signals

Evaporator energy saving

Explains how to enable or disable the energy-saving mode for the evaporator, affecting fan operation.

Operation modes

Free cooler

Master / Slave wiring

PCB Connections

19. Maintenance

Every 3-6 months

Specifies routine maintenance tasks for the condenser coil, such as cleaning, to ensure efficient operation.

Every 12 months

Lists annual maintenance checks, including security of fixings, pipeline inspection, and motor checks.

When necessary

Describes cleaning procedures for evaporator and condenser fins, advising against high-pressure washing.

20. Standards applied to the product range

Noise levels

Presents sound pressure levels and air volumes for BMOP condensing units under different temperature conditions.

BMEIP

22. Weights

23. Sales outlines

BMOP130 - BMOP250

Dimensional outlines and connection details for BMOP130 to BMOP250 condensing units.

BMOP 320 350 360

Dimensional outlines and connection details for BMOP320, BMOP350, and BMOP360 condensing units.

BMIEP-37 & 48

Dimensional outlines and connection details for BMIEP-37 and BMIEP-48 evaporator units.

BMIEP-69 & 89

Dimensional outlines and connection details for BMIEP-69 and BMIEP-89 evaporator units.

BMIEP-133

Dimensional outlines and connection details for the BMIEP-133 evaporator unit.

24. Electrical

BMOP running amps

Provides electrical specifications including full load current, LRA, fuse/MCB sizes, and minimum cable sizes for BMOP units.

BMIEP running amps

Details electrical data for BMIEP units, including fan motor and heater specifications, and fuse/MCB ratings.

BMOP 1PH – (BMO-PLUS-1PH-Schem: Rev1)

BMOP 3PH – (BMO-PLUS-3PH-Schem: Rev1)

BMIEP All Units

25. Guarantee / warranty procedure

Sales support & technical support contact details.

Provides contact information for technical support, sales, and spare parts for the product range.

Related product manuals