Do you have a question about the Woodward SPM-D Series and is the answer not in the manual?
Category | Recording Equipment |
---|---|
Operating Temperature | -20 to +70 °C (-4 to +158 °F) |
Storage Temperature | -40 to +85 °C (-40 to +185 °F) |
Humidity | 95% non-condensing |
Dimensions | 144 x 144 x 100 mm (5.67 x 5.67 x 3.94 in) |
Weight | 0.8 kg (1.76 lbs) |
Protection Class | IP20 |
Power Consumption | 15 W |
Defines the specific applications and operational constraints for the unit.
Details essential precautions to prevent damage from static electricity to electronic components.
Illustrates the electrical connections for different unit configurations and power supplies.
Details reference point connection and power supply wiring for different unit types.
Describes how to connect system voltages for synchronization assessment.
Outlines the function and connection of digital inputs for control signals.
Explains the control outputs for synchronizing pulse and close command.
Details the three-position controllers for voltage and frequency adjustments.
Explains the operational logic based on input signals and conditions.
Specifies the voltage and frequency requirements for synchronization states.
Details the function of discrete inputs for enabling operations and parameter selection.
Describes states like no-load, synchronizing with slip, and zero phase control.
Explains synch check mode, isolated operation, and black start procedures.
Details LED indicators and relay outputs for operational status and commands.
Provides a visual guide to the unit's front panel layout and components.
Describes the function and color indication of each LED on the front panel.
Details the function of each push button for navigation and control.
Explains how the LC display shows voltage, frequency, and alarm information.
Covers language selection and software version display for initial setup.
Explains the three-level security hierarchy for accessing configuration settings.
Details parameters for rated frequency, voltage, and setpoints.
Covers no-load, frequency, and voltage controller settings and modes.
Defines settings for synchronization functions, slip, phase angle, and time monitoring.
Details the setup for black start functions, voltage, and frequency conditions.
Explains the settings for relay message outputs like 'Connect 2'.
Covers setting custom codes for different user levels and disabling protection.
Outlines the step-by-step process for safely installing and testing the unit.
Provides detailed physical dimensions and mounting information for the unit.
A comprehensive list of all configurable parameters with their ranges and default values.
Specifies the electrical measurement capabilities and accuracy of the unit.
Details the power requirements and intrinsic power consumption.
Covers discrete input ranges and relay output capabilities.
Describes the physical enclosure, dimensions, and environmental protection ratings.
Specifies the available communication interfaces, such as USB.
Lists available factory options for servicing Woodward equipment.
Provides instructions for returning units for service, including required information.
Details recommended materials and procedures for packing equipment for shipment.
Lists contact information for technical assistance and service inquiries.
Describes available engineering support, training, and on-site field services.
Provides a template for collecting necessary information before contacting technical support.