EasyManua.ls Logo

Woodward SPM-D10 User Manual

Woodward SPM-D10
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
37215C
SPM-D10
Synchronizing Unit
Manual
Version 6.1xx
Manual 37215C
Question and Answer IconNeed help?

Do you have a question about the Woodward SPM-D10 and is the answer not in the manual?

Woodward SPM-D10 Specifications

General IconGeneral
BrandWoodward
ModelSPM-D10
CategoryRecording Equipment
LanguageEnglish

Summary

General Safety and Definitions

General Safety Warnings

Emphasizes reading the entire manual and following safety precautions for installation, operation, and servicing.

Prime Mover Overspeed Protection

Stresses the need for a separate overspeed shutdown unit for prime movers.

Static Sensitive Components Precautions

Details precautions for handling static-sensitive electronic controls.

Important Definition Symbols

Defines the WARNING, CAUTION, and NOTE symbols used in the manual.

Display and Operating Elements

Overview of Controls

Provides an overview of the unit's LEDs, push-buttons, and LC display.

LED Indicators

Details the functions and indicators of the unit's LEDs.

Pushbutton Functions

Details the functions and operation of the unit's pushbuttons.

Display Monitoring Modes

Explains display monitoring in automatic mode for voltage, frequency, and alarms.

General Information

SPM-D10 Functions

Lists core functions like Synchronization, Synch-check, and Dead bus start.

SPM-D Model Designation

Explains the designation format for different SPM-D models and their options.

Model Options and Variations

Describes options like mounting, hardware variations, CTs, and voltage transformers.

Electrostatic Discharge Awareness

ESD Precautions for Control Handling

Details precautions for handling static-sensitive electronic controls.

Grounding and Clothing Recommendations

Advise to discharge body static and wear cotton clothing to prevent static buildup.

Keep Static-Generating Materials Away

Keep plastic, vinyl, and Styrofoam materials away from the control unit.

PCB Handling and Warranty

Warns that opening the control unit voids the warranty; provides PCB handling precautions.

Installation

Installation Safety Requirements

Mandates a circuit breaker and mentions interference suppressors for inductive devices.

Wiring Diagrams

Provides wiring diagrams for SPM-D10 and SPM-D10/X variants.

Reference Point and Power Supply

Covers reference point connection and details for 24 Vdc and 90-250 Vac/dc power supplies.

Generator and Mains Measuring Inputs

Explains connections for generator voltage and mains/busbar voltage measurements.

Discrete and Relay Inputs/Outputs

Details discrete inputs, their voltage limits, and relay outputs for control and messages.

Controller Outputs

Describes controller outputs for SPM-D10 and SPM-D10/X, including three-position and analog/PWM types.

Related product manuals