INSTALLATION
Greenstar i System Compact - 6 720 807 726 (2013/05)30
EXTERNAL 230V PROGRAMMER AND TWO HEAT ZONES WITH UNVENTED CYLINDER (S-PLAN PLUS)
Fig. 53 External controls with unvented cylinder
EXISTING INSTALLATIONS
For boiler replacements on an existing system, it is not necessary to zone
the upstairs and downstairs separately, compliance with the zone
requirements can be achieved by a single room thermostat or
programmable room thermostat.
While the system is drained down, a TRV must be fitted to all radiators
except in bathrooms and the room with the thermostat.
SYSTEM WIRING CENTRE
External components are connected to the Wiring centre junction box.
Fig. 54
All of these points are wired to this point
All of these points are wired to this point
All of these points are wired to this point
Table 11 Connection legend