41
d
1300 922 271
service.australia@einhell.comAFTER SALES SUPPORT
7
Data
Technical data
AC motor ......................................................................................... 230-240 V ~ 50 Hz
Power P .................................................................................................. S6 40% 1700 W
Idle speed n
0
................................................................................................ 6,500 min
-1
Carbide saw blade Ø 250 x Ø 30 x 2.4 mm .............................................. 24 teeth
Carbide saw blade Ø 250 x Ø 30 x 3.0 mm .............................................. 48 teeth
Table size .................................................................................................. 610 x 445 mm
Table width extension, left/right .................................................... 608 x 250 mm
Table length extension, rear .............................................................. 435 x 320 mm
Max. cutting height ................................................................................. 72 mm / 90°
.......................................................................................................................... 54 mm / 45°
Height adjustment ........................................................................ infinite 0 - 72 mm
Tilting saw blade ................................................................................. infinite 0° - 45°
Dust extraction connector .......................................................................... Ø 36 mm
Net weight ............................................................................................ approx. 24.5 kg
Operating mode S6: Continuous operation
To prevent the motor from overheating, only use the bench-type circular
saw as follows:
After an operating period of 4 minutes (S 6 = 40%) under the permitted
load, you must interrupt your work for a period of 6 minutes in which the
machine can run idle.
Noise emission values
The noise emission values were measured in accordance with
EN 61029-2-1.
On-load operation
L
pA
sound pressure level ................................................................................ 94 dB(A)
K
pA
uncertainty .......................................................................................................... 3 dB
L
WA
sound power level ................................................................................. 105 dB(A)
K
WA
uncertainty ......................................................................................................... 3 dB
WZTS_1701_AUS_SPK7.indb 41 06.05.13 11:19