EasyManua.ls Logo

Woxcon MUH44-H2 - User Manual

Woxcon MUH44-H2
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MUH44-H2
4x4 HDMI 2.0 Matrix with Audio Matrix/
Downscaling/ AOC Supported
All Rights Reserved
Version: MUH44-H2 _2019V1.2
User Manual

Questions and Answers

  • M
    Michelle ClarkAug 7, 2025
    What to do if there is no output image when switching on Woxcon MUH44-H2 Matrix Switcher?
    • J
      James TaylorAug 7, 2025
      If the Woxcon Matrix Switcher shows no output image when switching, it could be due to several reasons: * There might be no signal at the input or output end. Verify the signal using an oscilloscope or multimeter. * A loose connection can cause this issue. Ensure all connections are secure. * If the input source uses HDCP, but HDCP compliance is off, send the command /%[Y]/[X]:1 or change the HDCP compliance status in the GUI. * The display may not support the input resolution. Try switching to another input source or enabling the display to learn the EDID data of the input.
  • C
    collinsronaldAug 12, 2025
    Why does the power indicator remain off when I turn on my Woxcon MUH44-H2?
    • J
      James TaylorAug 12, 2025
      If the power indicator on your Woxcon Matrix Switcher remains off when powered on, it is likely due to a loose or failed power connection. Check to ensure that the power cables are connected correctly.
  • H
    hessjohnAug 16, 2025
    What to do if I cannot control Woxcon MUH44-H2 Matrix Switcher via IR remote?
    • L
      Lisa SantiagoAug 16, 2025
      If you can't control your Woxcon Matrix Switcher using the IR remote, consider these possible causes: 1. The battery may be dead. Replace it with a new one. 2. The IR remote itself might be broken. Send it to an authorized dealer for repair. 3. You may be beyond the effective range of the IR signal, or not pointing at the IR receiver. Adjust the distance and angle to point directly at the IR receiver. 4. The IR receiver connected to the IR IN port might not have a carrier. Replace it with an IR receiver that has a carrier.
  • E
    Elizabeth WallaceAug 20, 2025
    How to unlock front panel buttons on Woxcon MUH44-H2 Matrix Switcher?
    • L
      Levi JohnsAug 20, 2025
      If you cannot control the Woxcon Matrix Switcher via front panel buttons, it is likely that the front panel buttons are locked. To unlock them, send the command /%Unlock; or select 'unlock' in the GUI interface.
  • P
    Patty ArnoldAug 25, 2025
    Why is there a blank screen on the display when switching with Woxcon Matrix Switcher?
    • T
      Tony MasonAug 26, 2025
      If there is a blank screen on the display when switching with your Woxcon Matrix Switcher: * The display might not support the resolution of the video source. Try switching again. * You can also manage the EDID data manually to make the resolution of the video source automatically compliant with the output resolution.
  • J
    Jennifer NicholsAug 29, 2025
    What causes EDID management to not work normally on Woxcon MUH44-H2 Matrix Switcher?
    • M
      Michelle LaraAug 29, 2025
      If EDID management is not working normally on your Woxcon Matrix Switcher, the HDMI cable at the output end might be broken. Replace it with a new HDMI cable that is in good working condition.
  • M
    Michael BrooksSep 2, 2025
    What to do if I cannot control Woxcon MUH44-H2 through RS232 port?
    • M
      Maria BrownSep 2, 2025
      If you cannot control the Woxcon Matrix Switcher by a control device (e.g., a PC) through the RS232 port: * Check the connection between the control device and the unit to ensure it is correct. * Verify that you have entered the correct RS232 communication parameters: Baud rate: 9600; Data bit: 8; Stop bit: 1; Parity bit: none. * The RS232 port might be broken. Send it to an authorized dealer for checking.